  • Page 2 DFG280 Operating Manual V1.05 WWW.BARTELLGLOBAL.COM Bartell Morrison Inc. Bartell Morrison USA LLC 170 Traders Boulevard East 200 Commerce Drive, Unit A Mississauga, Ontario, Canada Freehold, NJ, USA L4Z 1W7 07728 Tel: (647) 953-4100 Tel: (848) 225-8100 Fax: (647) 953-4101 Fax: (848) 225-8101 SPE International Ltd.
  • Page 3 DFG280 Operating Manual V1.05 This manual is provided to persons purchasing an SPE machine and may not be reproduced in part or full without written permission of SPE International Ltd. This manual provides the basic information required and is only to be used as a guideline.
  • Page 4 DFG280 Operating Manual V1.05 INDEX Page No Safety Safety Precautions Operating Manual Starting Work General Operation Changing the Grinding Head Electrical Instructions Maintenance 13-18 Spare Parts Breakdown 19-21 Wiring Diagrams Electrical Requirements 23-24 Noise and Vibration Assessment Warranty Declaration of Conformity...
  • Page 5 Health & Safety Executive. Never leave the DFG280 unattended whilst in use. Always stop the motor prior to leaving the machine. Keep the electric lead away from the grinding head.
  • Page 6: Safety Precautions

    DFG280 Operating Manual V1.05 SAFETY PRECAUTIONS DANGER EXPLOSION HAZARD Never operate the machine in an explosive atmosphere, near combustible materials, or where ventilation does not clear exhaust fumes. WARNING BURN HAZARD Never come into contact with the engine or muffler when engine is operating or shortly after it is turned off.
  • Page 7 This manual covers, to the best of our knowledge, the operation and maintenance of the DFG280. Before operation of the equipment the manual should be read and understood by the operator. The safety regulations must be followed at all times. Service of electrical components should be carried out by authorised personnel.
  • Page 8: Starting Work

    DFG280 Operating Manual V1.05 STARTING WORK Check the following prior to starting the equipment. • Check all nuts and bolts for tightness • Check the plugs and cables for damage 1. The machine is fitted with an adjustable handle which can be folded over for ease of lifting and transportation.
  • Page 9: General Operation

    The DFG280 is normally operated in a forwards and left to right direction, the operator varying the speed of travel to determine the final finish. It is permissible to operate the machine with a backwards and forwards action.
  • Page 10 DFG280 Operating Manual V1.05 CHANGING THE GRINDING HEAD 1. Disconnect from the power supply. 2. Tilt the machine backwards on to its handle. The machine must be secured and supported. 3. Make sure the grinding head is cool to the touch.
  • Page 11: Electrical Instructions

    All cables should be fully uncoiled and never left wrapped around cable reels or tied in loops. If the power is to be generated, the DFG280 requires a minimum 8kva generator. The motor is protected with a safety trip in the panel. Should the trip be activated, it will reset automatically after cooling down.
  • Page 12: Maintenance

    DFG280 Operating Manual V1.05 MAINTENANCE Prior to any maintenance or adjustment disconnect the machine from the power supply. AFTER USE: Clean the machine to remove all build-up of dust and surface residue. If using a hose pipe or pressure washer take care that water is not directed onto electrical components and switches.
  • Page 13 DFG280-3 (230V) DFG280-5 (110V) ITEM ITEM SPENo DESCRIPTION QTY. SPENo DESCRIPTION QTY. 5350 Main Body Plate 5360A Motor (230V) 5351 Handle (Bottom Section) SPM1P1400 Switch 5352 Handle (Top) SPM1X14230 Under Voltage Coil 5353 Connector 5354 Adapter Plate 5356 Shroud 5357...
  • Page 14 " "'o "' "' '------ '------- DWG No. DFG-280-A-(ME)-1 DFG280 NOT TO SCALE 2 of 6 SCALE SHEET •...
  • Page 15 '-----._ '- '- '-----._ " " " "· "-, ° " 0----._ ' - -y. 53 58 35 "'-------._ "'-o 60 59 36 46 55 43 "' DWG No. DFG-280-A-(ME)-2 DFG280 FASTENERS NOT TO SCALE SCALE SHEET 3 of 6...
  • Page 16 44 53 25 (DFG280-6 Only) DWG No. DFG-280-A-(SA)-2 HEAD DFG280 NOT TO SCALE 4 of 6 SCALE SHEET...
  • Page 17 ADAPTER PLATE (Standard Fitment) DWG No. DFG-280-A-(SA)-3 COUPLING DFG280 NOT TO SCALE 5 of 6 SCALE SHEET...
  • Page 18 OPTIONAL TOOLING PLATES SPENo. DESCRIPTION 5355 T-Mag Plate 5381 Slide Mag Plate T-MAG PLATE SLIDE MAG PLATE DWG No. DFG-280-A-(OE)-4 TOOLING NOT TO SCALE 6 of 6 SCALE SHEET...
  • Page 19 DFG280 Operating Manual V1.05 WIRING DIAGRAM DFG280-1 DFG280-6...
  • Page 20: Wiring Diagram

    DFG280 Operating Manual V1.05 WIRING DIAGRAM DFG280-3...
  • Page 21 DFG280 Operating Manual V1.05 WIRING DIAGRAM DFG280-5...
  • Page 22: Electrical Requirements

    DFG280 Operating Manual V1.05 ELECTRICAL REQUIREMENTS DFG280-1 Volts Plug Size Cable Size (mm) Norm Cable Length Transformer Generator 415V 16 Amp 5 Pin 2.5 - 3 Core 30 metres 8 kva DFG280-3 Volts Plug Size Cable Size (mm) Norm Cable Length Transformer Generator 230V 16 Amp 3 Pin 2.5 - 3 Core...
  • Page 23: Specification Sheet

    DFG280 Operating Manual V1.05 SPECIFICATION SHEET Specifications DFG280-1 Type Electric 3 Phase Power Output 2.2kw Voltage 415V Cycles 50hz/60hz Head Speed r.p.m. 1720 Engine motor speed r.p.m. 1720 Machine Dimensions (mm) Length 1000 / 660* Width Height 940 / 550*...
  • Page 24 DFG280 Operating Manual V1.05 Specifications DFG280-5 Type Electric 1 Phase Power Output 2.2kw Voltage 110V Cycles 50hz Head Speed r.p.m. 1400 Engine motor speed r.p.m. 1400 Machine Dimensions (mm) Length 1020 / 660* Width Height 940 / 560* Weight (kg)
  • Page 25 DFG280 Operating Manual V1.05 RECORD OF NOISE AND VIBRATION ASSESSMENT Manufacturer: Type: Compact Floor Grinder Model No. DFG280-5 Electric Operation : Concrete floor surface Inserted Tool: Diamond Plate HAV Note: Independent HAND-ARM VIBRATION Frequency Weighted Energy Equivalent Accelerations (a Measurement...
  • Page 26: Warranty

    Bartell agrees to furnish without charge, F.O.B. our plant, a replacement for any part or portion thereof, comprising the main unit of the DFG280, consisting of the head housing assembly, save and except power units, prove upon our examination, to be defective in either material or workmanship within a period of twelve (12) months from date of purchase, provided that notice of such defective part or portion thereof is given to Bartell Ltd.
  • Page 27: Declaration Of Conformity

    DFG280 Operating Manual V1.05 DECLARATION OF CONFORMITY SPE INTERNATIONAL LTD Honeyholes Lane Dunholme Lincoln LN2 3SU DECLARE that under our sole responsibility for the supply/manufacture of the product (Description/name) DFG280 (Model/type) DFG280 to which this declaration relates is in conformity with the following standards and other normative documents following the provisions of Directive 2006/42/EC.
  • Page 28 DFG280 Operating Manual V1.05 CONDITIONS OF SALE The quotation overleaf and any order placed following such quotation are subject to the following conditions of sale in which SPE International Limited is referred to as the “Company”. Validity of quotation No order received from a customer by the Company shall constitute a contract until accepted in writing by the Company.