Festo KMP3 Series Assembly Instructions page 2

Connecting cable

Advertisement

Fig. 5
3. Turn contact holder [B] 180°. Avoid cable twist during turning.
Fig. 6
4. Fasten the contact holder [B] loosely in the previously unused holes [C] with
the two screws [A].
4.5
Wiring
Character­
Cable characteristic
istics
KMP3
Standard
KMP4
Suitable for energy chains
Tab. 2 Wiring
4.6
Mounting in energy chain
1. Lay the chain out lengthwise.
2. Place the cables on the chain, making sure they are not twisted.
3. Separate cables from each other using separators/drilled holes.
4. Do not connect cables together.
Fig. 7
5. Maintain space X. X > 10% of the cable diameter D.
If the chain is suspended vertically: increase space X.
Fig. 8
6. Align chain in the operating position:
Make sure that the radius is greater than the bending radius R of the
cables.
Cables can move freely in the bending radius KR of the energy chain.
Ä Cables are not forced through the chain.
Wiring
Flexible (freely movable, unguided wiring)
The line can be dynamically bent, but not for robots
or energy chains.
In energy chain or flexible
7. Mount the energy chain è corresponding instructions.
8. Fasten cables:
with short energy chains (length < 1 m) at both ends of the chain
with long sliding energy chains (length > 1 m) only at the driver end
Fig. 9
9. Do not move cables all the way to the fastening point.
Ä Mounting space A between the fastening point and bending movement is
maintained.
NOTICE!
Damage to cables if the chain breaks.
Replace cables after a chain break.
NOTICE!
Malfunction and material damage due to vertically suspended cables.
The cables stretch.
Regularly check the length of the cables.
Readjust the cables if required.
5
Technical data
KMP...
Cable characteristic
Cable composition
Cable diameter
D
Mounting space
A
Current rating at 40 °C
Surge resistance
Operating voltage range
DC
U
B
Bending radius
Fixed cable installation
R
Flexible cable installation
R
Ambient temperature
Fixed cable installation
Flexible cable installation
Material
Cable sheath
Electrical connection 1
Function
Connection type
Connection technology
Type of mounting
Electrical connection 2
Function
Connection type
Connection technology
Wire ends
Tab. 3 Technical data
3­9P...
3­25P... 4­9P...
Standard
Suitable for energy
chains
[mm²]
10x0.34
18x0.34
10x0.25
[mm]
7.15
8.5
PVC: 7.4
PUR: 7.0
[mm]
PVC:
³ 148
PUR:
³ 140
[A]
3
[kV]
1
[V]
0 ... 30
[mm]
PVC: ³ 24
³ 30
³ 45
PUR: ³ 23
[mm]
PVC: ³ 39
³ 75
³ 90
PUR: ³ 37
[°C]
–25 ... +70
–40 ... +70
[°C]
–5 ... +70
PVC: –5 ... +70
PUR: –40 ... +70
PVC
PVC: PVC
PUR: TPE-U(PUR)
Field device side
Socket
Sub-D
2x M3 screw
Controller side
Cable
Open end
Cut off bluntly
4­25P...
25x0.25
PVC: 10.4
PUR: 9.8
PVC:
³ 208
PUR:
³ 196
PVC: ³ 33
PUR: ³ 31
PVC: ³ 55
PUR: ³ 51