Care And Cleaning; Operation; Technical Data - Sygonix SY-4504970 Operating Instructions Manual

Timer switch with light sensor, white timer switch with light sensor for outdoor use, black
Table of Contents

Advertisement

Available languages

Available languages

Controls
6
ON
5
4
3
2
1
1 Earthed socket (consumer
4 OFF position
connection)
5 ON position
2 Position
(guided by
6 Power LED
brightness)
7 Light sensor
3 Rotary switch
8 2Hr timer symbol (2 h)
The drawing is representative of both products. The product with item no. 2252486
also has a protective cover for the earthed socket, which is not shown here.

Operation

• Determine an installation location for the brightness-guided timer switch that is sufficiently
illuminated by daylight. Do not cover the light sensor (7) to avoid faulty switching.
The timer switch must be plugged into the power socket so that its built-in socket
comes to be located above the switch with the cover hinge at the top. Water drips
off downward when the cover is opened. Some imprints will not be properly legible
in that position. This only applies to the product with the item no. 2252486 (Timer
switch IP44).
• Plug the product with the mains input connector (12) into an earthed mains socket connec-
ted to the public grid. The power LED (6) on the front top lights up.
Do not use any extension cables, but plug the product directly into the mains socket!
• Plug an electrical consumer into the earthed mains socket (1). The power consumption of
the connected consumer must not exceed 3680 W. Do not overload the socket.
• If the device that you are connecting has an on/off switch, switch off before connecting, then
switch it on again after connecting..
• Set the desired operating/switching mode with the rotary switch (3). Turn the rotary switch
clockwise or anti-clockwise until the arrow on the rotary switch points to the desired symbol.
• The timer switch then switches on/off accordingly. The power LED (6) lights up when the
earthed socket is switched on.
• The following manual and automatic switching modes are available:
Symbol
Meaning
ON
The earthed socket is permanently switched on.
OFF
The earthed socket is permanently switched off.
2H
The earthed socket switches on as soon as the ambient brightness has
fallen below 25 lux for more than 5 minutes.
The switch-on duration is 2 hours.
4H
The earthed socket switches on as soon as the ambient brightness has
fallen below 25 lux for more than 5 minutes.
The switch-on duration is 4 hours.
6H
The earthed socket switches on as soon as the ambient brightness has
fallen below 25 lux for more than 5 minutes.
The switch-on duration is 6 hours.
8H
The earthed socket switches on as soon as the ambient brightness has
fallen below 25 lux for more than 5 minutes.
The switch-on duration is 8 hours.
The earthed socket switches on as soon as the ambient brightness has
fallen below 25 lux for 2 seconds and switches off again as soon as the
brightness returns to min. 40 lux.
7
8
9
10
11
12
9 4Hr timer symbol (4 h)
10 6Hr timer symbol (6 h)
11 8Hr timer symbol (8 h)
12 Mains input connector

Care and cleaning

• Disconnect the product from the mains socket and connected consumers before cleaning.
• This product does not contain any components that require maintenance. Never attempt to
open or disassemble it.
• Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may
damage the enclosure or cause the product to malfunction.
• Keep the cover over the light sensor clean to allow light to enter freely.
• Use a clean, dry, lint-free, soft cloth to clean the product. Do not press too hard on the
enclosure, as this can lead to scratch marks.
Disposal
Electronic devices are recyclable waste and must not be placed in household waste.
At the end of its service life, dispose of the product in accordance with applicable
regulatory guidelines.
You thus fulfil your statutory obligations and contribute to environmental protection.

Technical data

a) Item no. 2252485
Nominal input voltage/current ....... 230 V/AC, 50 Hz, 16 A
Output voltage/current .................. 230 V/AC, 50 Hz, 16 A (socket max. 3680 W)
Socket ........................................... 1x alternating voltage
Enhanced contact protection ........ Yes
Protection class ............................ IP20
Running accuracy (timer) ............. ±2 minutes per hour
Switching brightness ..................... Switch-on 25 lux/switch-off 40 lux
Operating conditions ..................... 0 to +40 °C, max. 85 %
relative humidity (non-condensing)
Storage conditions ........................ 0 to +40 °C, max. 85 %
relative humidity (non-condensing)
Dimensions (W x H x D) ............... 57 x 104 x 71 mm
Weight .......................................... 101 g
b) Item no. 2252486
Nominal input voltage/current ....... 230 V/AC, 50 Hz, 16 A
Output voltage/current .................. 230 V/AC, 50 Hz, 16 A (socket max. 3680 W)
Socket ........................................... 1x alternating voltage
Enhanced contact protection ........ Yes
Protection class ............................ IP44
Running accuracy (timer) ............. ±2 minutes per hour
Switching brightness ..................... Switch-on 25 lux/switch-off 40 lux
Operating conditions ..................... -20 to +40 ºC
Storage conditions ........................ -30 to +50 ºC
Dimensions (W x H x D) ............... 87 x 58 x 114 mm
Weight .......................................... 127 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or capture in electronic
data processing systems, requires the prior written approval of the publisher. Reprinting, also in part, is prohibited. This
publication reflects the technical status at the time of printing.
Copyright 2020 by Conrad Electronic SE.
*2252485_86_v3_1220_02_DS_m_4L_(1)