Albixon OXILIFE Installation And User Manual

Albixon OXILIFE Installation And User Manual

Advertisement

Quick Links

Hydrolysis - electrolysis
low intensity
OXILIFE
INSTALLATION
AND USER GUIDE
Portable
from
color
display (TFT)
1,5g
Upgrade
salt/l
possible
VERZE 11. 02. 2020 / REVIZE: 11. 02. 2020
Worldwide
WIFI and
remote
MODBUS
control
Self
Sea
clean
water
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OXILIFE and is the answer not in the manual?

Questions and answers

Summary of Contents for Albixon OXILIFE

  • Page 1 Hydrolysis - electrolysis low intensity OXILIFE INSTALLATION AND USER GUIDE Portable Worldwide from WIFI and color remote MODBUS display (TFT) control 1,5g Upgrade Self salt/l possible clean water VERZE 11. 02. 2020 / REVIZE: 11. 02. 2020...
  • Page 2: System Installation

    Hydrochloric acid container (optional, for models with pH control, not supplied with unit) Filtration of the Other pool equipment General Installation Module RF or RF/WIFI or WIFI Guide Relay FILTER PUMP 110-230 V / Hydrolysis - electrolysis low intensity OXILIFE...
  • Page 3: Monthly Checks

    (clear liquid). After each cleaning the probes must be calibrated. Also: the probes should never dry out and must be kept wet if stored (when emptying the pool for winterizing, make sure to store the measuring head in water). Hydrolysis - electrolysis low intensity OXILIFE /...
  • Page 4: Troubleshooting

    HANDLING AND DOSING DANGEROUS CHEMICALS Chemicals should be handled with extreme precaution. When preparing acid, always add acid to water, never add water to acid, because very dangerous gasses may be produced. / Hydrolysis - electrolysis low intensity OXILIFE...
  • Page 5 Diameter tube connection 63 mm Dimension cell 355 x 305 x 305 mm Cell cable size (3 x 4) x 1,5 m Gas sensor Incorporated in the cell Maximum pressure 4 kg/cm Maximum temperature 45°C Hydrolysis - electrolysis low intensity OXILIFE /...
  • Page 6: Automatic Controls

    Material Ag/Cl Gold Copper / gold Stainless steel Probe holder ABS 50/63 mm Supplementary equipment Includes 2 m of flexible tube/valve Cable Plug BNC with protection BNC with protection Connectors Connectors Connectors Dimensions / Hydrolysis - electrolysis low intensity OXILIFE...
  • Page 7 Notes Hydrolysis - electrolysis low intensity OXILIFE /...
  • Page 8 Thank you for using ALBIXON products ALBIXON export@albixon.com www.ALBIXON.com Note that the photos used in the manual are illustrative only. Printing and typesetting errors reserved.

Table of Contents