6. To choose a product in Phoenix:
From the File menu, choose "Choose Product" and select RA-8 from the list
or
from the File menu, choose "Scan Product".
7. From the toolbar, set operating mode to "Local".
8. From the Testing menu, choose "RF Controls".
9. In the "RF Controls" window:
- Select band "GSM900" or "GSM 1800" or "GSM1900" (Default = "GSM900").
- Set Active unit to "Tx" (Default = "Rx").
- Set Operation mode to "Burst" (Default = "Burst").
- Set Tx data type to "Random" (Default = "All1").
- Set Rx/Tx channel to 37 on GSM900 band or 700 on GSM1800 band or 661 on
GSM1900 (Defaults).
- Set Tx PA mode to "Free" (Default).
- Set power level to 5 (Default = 19) on GSM900 or to 0 (Default = 15) on GSM1800
or GSM1900.