2.6.8 REQUEST TEXT DATA command

This command requests the device to send text data.
1) Command format
Byte/bit
0
1
2
3
4
5
6
7
8
CODE
0x30 ('0')
0x31 ('1')
0x32 ('2')
0x33 ('3')
0x34 ('4')
0x35 ('5')
0x36 ('6')
0x37 ('7')
0x38 ('8')
0x39 ('9')
0x3A (':')
Track
number
'000'
'001'
'099'
'999'
D&M
7
6
Table 28. Request Text Data command
Data Type
CD Text (Title)
CD Text (Artist)
Reserved
Reserved
MP3/WMA Folder Name
MP3/WMA File Name
Reserved
ID3 Title Name
ID3 Artist Name
ID3 Album Name
Reserved
Table 29. Data Type
Content
Whole Disc's
Track 1
:
:
Track 99
:
:
Track 999
Table 30. Track number
5
4
3
STX (0x02)
Command code ('6')
Data Type (Table 29)
Track number 100 digits (Table 30)
Track number 10 digits (Table 30)
Track number
1 digits (Table 30)
ETX (0x03)
BCCH (high-level)
BCCL (low-level)
Note
Only Play/Pause/Cue.
Only Play/Pause/Cue.
Only Play/Pause/Cue.
Note
If CD Text Disc Then whole Disc's.
Maximum value in the case of the CD.
DCM390 Serial Interface Specification