General Information - Pentair Flotec FPCC5030 Installation And Operation Manual

Battery backup system
Table of Contents

Advertisement

Available languages

Available languages

GENERAL INFORMATION

GENERAL INFORMATION
The Battery Backup Combo Kit is pre-plumbed up to the hose
and clamp assembly. The system includes the primary sump
pump (PSP), backup sump pump (BSP) assembly, and vertical
float switch. The unit is equipped with two check valves - one for
the primary pump and one for the backup pump.
The battery backup pump is not a substitute for your primary
sump pump. It is designed to temporarily backup your primary
sump pump during a power outage or other problem which
prevents normal operation of the primary pump. Do not use this
system to pump flammable liquids or chemicals. Pump clear
sump water only with this pump. For residential use only.
Keep the battery charger dry and protected from damage.
This system is designed to work with either a sealed lead-acid
AGM battery or a flooded lead-acid battery. Use of a true Gel Cell
(often confused for AGM) or a standard automotive battery with
this charger is not recommended. An automotive battery may
require charging after only 1-2 hours of continuous use, and the
repeated charging cycles may cause early plate failure in the
battery.
SPECIFICATIONS
Maximum vertical pumping distance is 15 feet (4.6M) for Model
FPCC5030
Power supply required
Primary Sump Pump..........................115V, 60 HZ.
Backup Sump Pump........................12V DC Battery
Liquid Temp. Range..........................32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.).............15 Amps
Discharge:
Hose & Clamp Assembly...................1-1/4"Slip / 1-1/2"Slip
Minimum pit diameter ....................................................14"
Minimum depth...............................................................10"
NOTE: Do not reduce size of discharge pipe or hose below 1-1/4"
diameter. If discharge is too small, pump will overheat and fail
prematurely.
NOTE: If a Carbon Monoxide (CO) sensor is installed, it must
be at least 15 feet away from battery charger in order to
avoid nuisance CO alarms. Please refer to your CO detector's
installation guidelines for more information.
.
4
PERFORMANCE - PRIMARY SUMP PUMP
GPM (LPM) AT TOTAL FEET (M) OF LIFT
5
SERIES
HP
(1.5M)
CAPACITY GALLONS(L)/M
Primary
3660
1/2
(FPZS50V)
(13855)
(11356)
PERFORMANCE - BACKUP SUMP PUMP
GPH (LPH) AT TOTAL FEET (M) OF LIFT
0
5
SERIES
(0)
(1.5M)
CAPACITY GALLONS(L)/HOUR
Backup
2700
2040
(PS17-2005)
(10221)
(7722)
ELECTRICAL & SWITCH SPECIFICATIONS
MOTOR
FULL
LOAD
SERIES
HP
AMPS
FPZS50V
1/2
4.1
PS17-2005
-
-
REQUIRED BATTERY CAPACITY:
Storage Batteries.
Storage Batteries.
PART
AMP-HOUR
BAT40
40
Unit equipped with dual battery capability
Maximum amp-hour: 120
38-120 Ampere-Hour Storage or Deep Cycle Battery
10
15
20
(3M)
(4.6M)
(6.1M)
3000
2160
960
(8176)
(3634)
10
14
(3M)
(4.3M)
1260
360
(4770)
(1363)
(4.6m)
BRANCH
SWITCH SETTING IN
CIRCUIT
INCHES (CM)
REQ.
(AMPS)
ON
7.5
19.1)
15
10.5
10.19 (25.9)
(26.7)
For best results, use the following AGM
For best results, use the following AGM
GAL/CHARGE
APPROX RUN
AT 10'
TIME
4,800
5 Hours
FP983 (06-08-20)
MAX.
LIFT
22 ft
(6.7m)
MAX.
LIFT
15
OFF
3
(7.6)

Advertisement