Operating and maintenance information for proportional valves
directional, flow, pressure controls
safety valves conforming to Machine Directive 2006/42/EC
This operating and maintenance information applies to Atos proportional directional, flow, pressure control valves and safety proportional valves.
It is intended to provide useful guidelines to avoid risks when the valves are installed in the hydraulic system.
It contains important information on the safe and proper installation, commissioning, operation transport and maintenance of the products.
The prescriptions included in this document must be strictly observed to avoid damages and injury.
The respect of this operating and maintenance information grants an increased working life, trouble-free operation and thus reduced repairing costs.
1
SYMBOL CONVENTIONS
Following symbols are used in this documentation to evidence particular risks to be carefully avoided.
In the following are listed the symbol conventions with their meaning, in case of non-compliance with this operating and maintenance information.
Death or serious injury could occur
WARNING
Minor or moderate injury could occur
CAUTION
Property damage could occur
NOTICE
Notes relevant to safety proportional valves
Information to be observed
2
GENERAL NOTES
This document is intended for machine manufacturers, assemblers and system end-users.
WARNING
Personal injury and property damage may be caused by incorrect use of the products!
The products have been designed for use in industrial environments and may only be used in the appropriate way.
Before using Atos proportional valves, the following requisites must be met to ensure appropriate use of the products:
• personnel who uses Atos proportional valves must first read and understand the operating and maintenance information,
particularly the Safety Notes in section
• the products must remain in their original state, no modifications are permitted
• it is not permitted to decompile software products or alter source codes
• damaged or faulty valves must not be installed or put into operation
• make sure that the products have been installed as described in section
2.1 Warranty
The expiration of warranty results from the following operations:
• incorrect assembly and commissioning
• improper use, see 5.2
Atos range of proportional directional valves, provides functional safety options /U and /K .
They are designed to accomplish a safety function, intended to reduce the risk in process control systems.
The valves are TÜV certified in compliance with IEC 61508 up to SIL 3 and ISO 13849 up to category 4, PL e
.
5
• improper handling and storage, see 9.4
• modification of the original condition
and
6
7
FS900-0/E
Table
risk classes to
ANSI Z535.6 / ISO 3864
FS900

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DLHZO-TES-SN-BC-140-T71 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Atos DLHZO-TES-SN-BC-140-T71

  • Page 1 Machine Directive 2006/42/EC This operating and maintenance information applies to Atos proportional directional, flow, pressure control valves and safety proportional valves. It is intended to provide useful guidelines to avoid risks when the valves are installed in the hydraulic system.
  • Page 2 Hydraulic symbol (simplified) Valve serial number 0123456789 DLHZO-TES-SN-BC-140-T71 Digital driver code E-RI-TES-N-BC-01H 40 0123456789 Valve code DLHZO-TES-SN-BC-140-T71 50 S18.02 L1: VALVE STATUS Digital driver serial number L2: NETWORK STATUS L3: SOLENOID STATUS Digital driver factory firmware version C1-C2: CANopen 1: CAN_SHLD...
  • Page 3 4.3 Piloted valve with on-board driver/axis card - DPZO-LES example Digital driver code E-RI-LES-N-BC-01H 40 0123456789 Valve code DPZO-LES-SN-BC-271-L5/I S18.02 L1: VALVE STATUS Digital driver serial number L2: NETWORK STATUS L3: SOLENOID STATUS Digital driver factory firmware version C1-C2: CANopen 1: CAN_SHLD E: INPUT- 2: not used (*)
  • Page 4 5.1 Intended use Atos proportional valves are intended for integration in industrial systems and machines or for the assembly with other components to form a machine or a system. They may only be operated under the environmental and operating conditions described in the valves technical tables.
  • Page 5 HYDRAULIC AND MECHANICAL INSTALLATION 6.1 Power packs tank and tubes cleaning The power unit tank has to be accurately cleaned, removing all the contaminants and any extraneous object. Piping has to be cold ben- ded, burred and pickled. When completely assembled an accurate washing of the piping (flushing) is requested to eliminate the contami- nants;...
  • Page 6 In the worst case, this may result in unexpected actuators movements and thus it constitutes a risk of injury. Ensure adequate hydraulic fluid cleanliness according to the cleanliness class required for the valve. Max fluid contamination level, see also filter section at www.atos.com or KTF catalog: • normal operation: ISO4406 class 18/16/13 NAS1638 class 7 •...
  • Page 7 SHIELD CONNECTION The correct shielding of signal cables has to be provided to protect the electronics from electrical noise disturbances, which could affect the valve functioning. In general following basic rules should be observed: • power supply cables and signal cables should be routed in separate cable conduits. •...
  • Page 8 • Any sudden increment in temperature requires the immediate stop of the system and the inspection of the relevant components 9.2 Repairing In case of incorrect functioning or beak-down it is recommended to send the valve back to Atos or to Atos authorized service centers which will provide for the reparation.

This manual is also suitable for:

Rzmo-p1-01-aes-bc-010/315/iDlhzo-les-sn-bc-040-t53/ikDpzo-les-sn-bc-271-l5/iDpzo-les-sn-bc-271-l5/ik

Table of Contents