Internally Selectable Functions

LED intensity general
OFF
BUTTON CLICK
ON
LED intensity ONAIR YELLOW
LED intensity ONAIR RED
TICKER
ON
OFF
Call Buzzer
The call buzzer can be disabled by repositioning a
jumper which is located on the side of the control panel
printed circuit board.
This jumper, S100, has two positions:
AB:
Buzzer Off
AC:
Buzzer On
The operational control panel is normally delivered
with the jumper S100 in position AC - buzzer on.
LED Intensity
There are three LED intensity potmeters on the control
panel:
- R25 for LED intensity general,
- R101 for LED intensity On Air Yellow,
- R100 for LED intensity On Air Red.
Button Click
The button click can be regulated by repositioning
jumper S2. This jumper, S2, has two positions:
AB:
Button click On
AC:
Button click Off
The jumper, S2, is located on the left side of the board
looking at it from the switch panel side. The operational
control panel is normally delivered with the jumper in
position AB.
10
Technical Manual LDK 4628 - Operational Control Panel
Reset
S1
button
OFF
ON
bit6
S11
bit7
S2
S10
bit6
bit7
S9
bit5
S8
bit4
bit4
S3
S7
bit3
bit5
S6.
bit2
S5.
bit1
S4
bit0
mp4
Watchdog
The function Watchdog On/Off can be selected by the
jumper S1 on the Data Subboard.
This jumper, S1, has two positions:
AB:
Watchdog On
AC:
Watchdog Off
The Data Subboard is normally delivered with the
jumper S1 in position AB (=Watchdog On).
User Jumpers
With Jumper S4 you can choose between Complete
Panel Lock or beneath Gain Field no Panel Lock.
This Jumper, S4, has two positions:
AB:
Complete Panel Lock
AC:
Beneath Gain Field no Panel Lock
The Data Board is normally delivered with the jumper
S4 in position AB (=Complete Panel Lock).
Jumpers S5 through S7 have no function assigned.
They should be always in position AB. The jumpers S8
through S11 form the OCP internal address number
when the OCP is used in multiple control mode. For
correct settings of these jumpers see the Series 9000
Application Guide.
Dip Switches
The Dip Switches S2 and S3 have factory settings.
Never change these settings. For correct settings of
these dip switches see the Series 9000 Application
Guide.
Data Subboard
mp2
mp1