4. MAINTENANCE
WARNING! With the exception listed below, all pump, float and electrical cable service maintenance and repair must only be
undertaken by an authorised service agent. Failure to observe this rule may be dangerous and will invalidate your warranty.
WARNING! Ensure the pump is disconnected from the mains power supply before attempting any service or maintenance.
4.1.
Keep all parts of the pump clean. Rinse, drain and allow to dry before storing pump.
4.2.
Regularly check the water inlet on the base of the pump to ensure there are no blockages. To access the impeller carefully undo the
base hex headed screws and remove base. Clean impeller and replace base ensuring that the O ring is correctly located.
DO NOT dismantle any other part of the unit.
TROUBLESHOOTING
1. Water level below min suction depth.
a. Motor operates but
2. Air bubbles in pump accumulated during submersion,
there is no suction.
3. Clogged intake filter or discharge pipe.
b. Reduced water
1. Discharge pipe bent, or pinched.
volume for level
2. Discharge pipe too narrow.
3. Pump partially blocked.
of water
c. The pump will not
1. No electrical power.
start or suddenly
2. Float not working.
stops during
3. Impeller is jammed.
operation.
NOTE: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of
experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible
for their safety. Children should be supervised to ensure that they do not play with the appliance.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack Sealey Limited
or float is incorrectly positioned so pump does not stop
at minimum level and sucks in air.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
1. Stop the pump.
2. Release air by inclining the pump and
re-immersing it in water.
3. Remove blockage, and clean the unit.
1. Straighten pipe.
2. Use wider diameter pipe.
3. Clean pump.
1. Check cable, plug and fuse.
2. Contact authorised service agent.
3. Clean the pump.