Download Print this page

Sealey WPD235A.V2 Quick Start Manual page 2

Submersible dirty water pumps - automatic

Advertisement

2. INTRODUCTION & SPECIFICATIONS
Manufactured from corrosion resistant materials with - stainless steel motor case and Noryl base cover - WPD235A.V2
Fitted with automatic cut-out. Designed for operation in dense and dirty water. Suitable for the effective drainage of cellars, sinks, cisterns,
baths and the general transfer of water and dense liquids.
Model No.
Cut-Out
WPD235A.V2 Automatic
WPS225A.V2 Automatic
fig.1
3. OPERATING INSTRUCTIONS
WARNING! Ensure you read, understand and apply safety instructions.
3.1.
Fit appropriate discharge pipe to pump outlet and secure with clip. Ensure the diameter of the discharge pipe is the same as, or
greater than, the outlet diameter. A smaller pipe will adversely effect the pump flow rate.
3.2.
Position pump in the water, and place the outlet pipe securely in the discharge receptacle or area. We recommend the pump is
submerged with its discharge outlet facing up to release any trapped air.
3.3.
Plug the pump into the electrical mains supply and switch on.
The pump will automatically turn on as the level of water rises (fig.1.A). As water level lowers, the float will automatically switch the
pump off as it reaches the minimum height (B). Float may be adjusted by shortening or lengthening the cable. The pump will switch on
if the water level is up to or above the maximum length of the float cable. To function correctly the float must move freely. Ensure the
float can do so and that the cable is not restricted. Check that the pump and discharge are working correctly.
3.4.
The water into which the pump is placed will act as the motor cooling agent. For this reason the pump must remain submerged at all
times. Should the pump have to be used in shallow water DO NOT operate for more than 10 minutes. Failure to follow this rule will
damage the unit and will invalidate your warranty.
NOTE: See fig.2 to determine minimum clearance required if using pump in a restricted area i.e. well, etc.
- stainless steel body and motor case
Outlet OD
Maximum
Output
38mm
217ltr/min
38mm
225ltr/min
WPD235A.V2
Maximum
Motor
Input
Head
8mtr
750W
230V
7.5mtr
750W
230V
fig.2
- WPS225A.V2
Maximum
Minimum
Particle Size
Water Depth
35mm
40mm
15mm
30mm
WPS225A.V2
Maximum
Water Depth
7mtr
5mtr

Advertisement

loading

This manual is also suitable for:

Wps225a.v2