Advertisement

X
INSTALLATION AND SERVICE
PROGRAMMING
This manual is for skilled service personnel only
'99 N°30 - 21053 CASTELLANZA (VA) - ITALY
DAMIAN S.
.
. - V
R
R
L
IA
AGAZZI DEL
Rev. M - 01
Vers. Software 0.5b or follow.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SNACK EUROPA and is the answer not in the manual?

Questions and answers

Aziz
April 8, 2025

How are you? I have a problem with my Europa Snacks machine. The lights are off and the machine won't cool down, but it has electricity. Have you encountered this problem before? Thank you. May God bless you.

1 comments:
Mr. Anderson
April 9, 2025

If the Damian Europa Snacks machine has electricity but the lights are off and it won't cool down, possible issues include:

1. The main switch might be in the “OFF” position.
2. The fuses may be blown and need checking.
3. Dust or foreign materials may be blocking the air passage of the refrigeration unit.
4. The condenser cooling fins might be dirty and need cleaning.
5. The set temperature may be incorrect.
6. The internal air circulation fan may not be working.
7. The refrigeration unit compressor or cooling fan might not be functioning.

Check each component and clean or replace as needed.

This answer is automatically generated

Summary of Contents for damian SNACK EUROPA

  • Page 1 INSTALLATION AND SERVICE PROGRAMMING This manual is for skilled service personnel only ‘99 N°30 - 21053 CASTELLANZA (VA) - ITALY DAMIAN S. . - V AGAZZI DEL Rev. M - 01 Vers. Software 0.5b or follow.
  • Page 2 Serie "EUR7" Page 18 Rev. M - 01...
  • Page 3 DENTIFICATION USE AND TECHNICAL DATA EUR7 This manual refers to series SNACK EUROPA automatic spiral vending machines, with number of drawers, number and type of vending spirals varying from model to model. IGURE IGURE MARKING PLATE / SERIAL NUMBER...
  • Page 4: Legend Of Symbols Used

    Serie "EUR7" These models are manufactured in variations “-A” without refrigeration unit, “-R” with Standard refrigeration unit, “-S” with Super refrigeration unit and “-L” with Super L refrigeration unit with the characteristics shown in the following table: Characteristics Variation EUR7B/x/xx-A EUR7B/x/xx-R EUR7P/x/xx-S EUR7L/x/xx-L Power supply...
  • Page 5: Warnings & Cautions

    Serie "EUR7" ARNINGS AUTIONS The appliance should be be started up by skilled service personnel ONLY. All operations described in this manual, especially all maintenance operations concerning the electrical part, should be carried out by skilled technical service personnel ONLY. The vending machine is equipped with a safety switch that allows powering up all electrical parts only when the door is closed.
  • Page 6: Installation

    Serie "EUR7" NSTALLATION Install the vending machine in covered and protected places where it is not exposed to inclement weather and cannot be rained on or sprinkled with jets of water. MIN 8 CM MIN 40 IGURE ± 2° Place the vending machine in the point where it is to be installed, making sure that the minimum distances shown in Figure 3 are guaranteed.
  • Page 7: Power Supply

    If it should become necessary to replace the vending machine‟s power cord, the H05VV-F replacement cord, which is in conformity with standard CENELEC EN 60 335-1, is available from Damian; the replacement should ONLY be carried out by skilled service personnel.
  • Page 8 Serie "EUR7" NSTALLATION OF PAYMENT SYSTEMS The payment system installation and removal operations must be carried out with the power supply switched off, moving the main switch to the “OFF” position. - MDB PAYMENT SYSTEMS Connect the payment system to the CPU card (2) being careful to connect the cable on the proper MDB connector on the CPU card (See Figure 5).
  • Page 9: Circuit Boards

    Serie "EUR7" IRCUIT BOARDS SLIDING PANEL PRODUCT DOOR EXECUTIVE connector FTCA connector ( 2 ) DISPLAY connector KEYBOARD connector ( 17 ) ( 18 ) ( 13 ) MDB connector ( 11 ) ( 10) ( 3) ( 5) ( 5) ( 6) IGURE ( 7 )
  • Page 10 Serie "EUR7" VERTEMPERATURE CONTROL EUR7P/ ONLY MODELS In order to guarantee the preservation of the products for sale, the vending machine controls that the internal temperature does not exceed a given threshold, called safety temperature, for a period longer than the overtemperature time; The overtemperature control function is managed through 3 parameters: (A) Safety temperature (B) Overtemperature time (Set).
  • Page 11 Serie "EUR7" NSWERS TO PROBLEMS THAT MIGHT ARISE RROR MESSAGES THAT APPEAR ON THE DISPLAY The following table shows the OFF messages that appear on the display when the vending machine is out of order. See Figure 5 for the numerical references in parentheses. - Press key “1”...
  • Page 12 Serie "EUR7" Message Message text Problem description / solution code OFF L10… FTCA vending sensor error – These error messages may appear when the vending machine is turned on or right before a sale. (Chk cable, Chang) – FTCA bars not connected OFF L10a FTCA sensors OFF - Check the condition of the wiring and of the connections of the FTCA bars (3)
  • Page 13 Serie "EUR7" Message Message text Problem description / solution code OFF L20… CL1 CPU (2) circuit board errors. These error messages concern failures of the ‟s vending machine circuit board. OFF L20a CL1 CPU Error (Restart - Change) - CPU card error - Turn the vending machine off and then on again;...
  • Page 14 Serie "EUR7" “W ” PON TURNING ON ARNING OUT OF ORDERS DETECTED IS DISPLAYED During normal vending machine operation, some malfunctions of some motors may occur. These malfunctions generate errors that can be automatically reset by the vending machine (R)* or that can be "not resettable"...
  • Page 15 Serie "EUR7" HE MACHINE DOES NOT REACH THE REQUIRED TEMPERATURE Before carrying out any operation on the refrigeration unit and, in particular, before checking any electrical part, move the main switch to the “OFF” position (See Figure 7). Check the condition of the fuses (See the “Fuse check” chapter). Make sure that dust and foreign materials do not block the refrigeration unit air passage.
  • Page 16 Serie "EUR7" USES MAIN SWITCH Press to cancel motors “OUT OF ORDER” SAFETY SWITCH Figure 7 Press to enter into programming The vending machine is equipped with fuses mounted as shown in the following table: OSITION NSCRIPTION PROTECTED CHECK WHEN CIRCUITS 5x20 T6.3 Refrigeration unit The vending machine does not...
  • Page 17: Routine Maintenance And Lubrication

    Serie "EUR7" OUTINE MAINTENANCE AND LUBRICATION During the maintenance and lubrication operations, do not perform any operation other than those indicated. See Figure 5 for the references in parentheses. Symbol Periodicity Check Lubricate - Correct operation of the door safety switch ...
  • Page 18: Environmental Protection

    If you wish to get dispose of this product, please contact the local authorities for information on the correct disposal method. ARRANTY Damian S.r.l. provides a warranty for its own products that is in conformity with the specific national laws. The warranty begins on the date shown on the sales document.
  • Page 19: Programming Sheet

    PROGRAMMING SHEET This attachment is an integral part of the manual and must remain with it ‘99 N°30 - 21053 CASTELLANZA (VA) - ITALY DAMIAN S. . - V AGAZZI DEL Rev. M - 01 Vers. Software 0.5b or follow.
  • Page 20: Programming Method

    Serie "EUR7" PROGRAMMING METHOD PS1 key Enter (P) Programming key O ENTER INTO PROGRAMMING Open the vending machine, power it up using the special key on the safety switch and press the pushbutton (P) found on the CPU card of the vending machine (see the above figure) for about 2 seconds; avoid reclosing the vending machine so as not to damage the safety switch.
  • Page 21: General Parameters

    Serie "EUR7" DEFAULT VALUE USED AUTOMATICALLY BY A NEW OR REINITIALISED CARD GENERAL PARAMETERS > ESSAGE LANGUAGE To establish the language of the messages that appear on the display. Programming [ Default: Italian ] General param. Language Current value > CONTRAST SETTING To set the contrast of the LCD.
  • Page 22 Serie "EUR7" essential components. Furthermore, if the vending machine is NOT programmed to contain perishable products ("Refrigerator operation” parameter other than “Food & Snack”), it allows setting a higher operating temperature only activated during those time intervals. The energy saving function setting modes are given below. »...
  • Page 23: Decimal Point

    Serie "EUR7" > EFRIGERATOR PERATION (Visualisation only, programmable by reinitialising the card) To visualise the operating mode of the refrigeration unit. Programming [ Default: Self-learned ] General param. Refrig.operation Current value The three possible operating modes, programmable by reinitialising the card, are: - Food &...
  • Page 24 Serie "EUR7" > Allows to read the internal parameter software 'code mode'. [ Read only ] Programming General param. Code Mode Current value > ISUALISATION OF THE VERSIONS INSTALLED To visualise the software versions installed. Programming General param. Software vers. ->->->...
  • Page 25 Serie "EUR7" When you have finished setting all of the motors that you wished to couple (Twin Motors), press 6 to continue the self-learning procedure. D) This message appears on the display: Self-learning FTCA sensors:XXX If the product drop sensors (FTCA) are installed on the vending machine, XXX = ON If the product drop sensors (FTCA) are not installed on the vending machine, XXX = OFF press 3 to confirm E) The following message will appear shortly on the display:...
  • Page 26 Serie "EUR7" » ROTECTED PARAMETERS Protected parameters are basic settings of the vending machine protected by „Password‟, parameters that were set at the factory whose variation is not recommended unless suggested by the technical support service. Improper variation of these parameters could compromise the correct operation of the vending machine. Programming General param.
  • Page 27 Serie "EUR7" „B‟ > NABLING OF THE BRACKET SELLING PRICES (Visible and programmable only with „Operating mode = MDB‟ and/or RFID payment system installed) To activate or deactivate management of the second price line bracket („B‟ price bracket). Settable values: Enabled (ON), Disabled (OFF). Programming [ Default: Disabled ] Price management...
  • Page 28 Serie "EUR7" Where L (line) indicates the number of the drawer (from the bottom) and C (column) indicates the position on the drawer. Where XX indicates the price line S1,S2,S3 dedicated to direct selections and VVVVV the relative price. Press the 1 and 2 keys to scroll through the available selections. Press the 3 key to confirm the current selection;...
  • Page 29 Serie "EUR7" > AXIMUM CREDIT To set the maximum credit value accepted by the MDB payment system. When the credit in the vending machine reaches this value, the machine no longer accepts coins or banknotes. Settable values: 0 ÷ 65535 (independent of the position of the comma, e.g. with 2 decimals the maximum credit is 655.35).
  • Page 30 Serie "EUR7" » SALES MODES (Visible and programmable only if „MDB coin return‟ payment system installed) To select the sales mode with an MDB payment system. Settable values: „0) Single NoChang‟, Single sale without change; at the end of the sale the change is cancelled. „1) Single+Change‟...
  • Page 31 Serie "EUR7" » ANKNOTES PRESENT (Visible and programmable only if an “MDB banknote reader” is installed) To read which and how many banknotes are present in an MDB payment system and to enable recognition of them: Programming MDB parameter Banknote stacker ->->->...
  • Page 32 Serie "EUR7" RFID PARAMETERS (Visible and programmable only if an „RFID payment system‟ is installed) To set the parameters of the RFID payment system. RFID – P > RICE BRACKET If an RFID payment system is installed in the vending machine, it allows selecting the price bracket to be associated with this system.
  • Page 33 Serie "EUR7" Settable values: 0 ÷ 45°C. To deactivate this function, set it to ≥40°C. Programming [ Default: 45 °C ] Refrig. Param's Security temper. Current value > VERTEMPERATURE TIME (Visible and programmable only with „Refrigerator operation = Food & Snack‟) To set the time beyond which the internal temperature must not exceed the safety temperature;...
  • Page 34 Serie "EUR7" AUDIT PARAMETERS NOTE: It is possible to display a minimum list of sales data on the automatic vending machine. If an MDB system is installed, the vending machine collects more detailed data, available in the EVA-DTS format. > ARTIAL COUNTER OF NUMBER OF VENDING MACHINE SALES To read the total number of vending machine sales since the last reset.
  • Page 35 Serie "EUR7" DIAGNOSTICS N.B. the programming TimeOut is disabled in the Diagnostics submenus, therefore, it is only possible to exit programming manually, using the appropriate keys. > UT OF ORDER MOTORS Select this item to see which motors have generated an Out of Order condition. The out of orders are also listed in this menu Programming Diagnostics...
  • Page 36 Serie "EUR7" The general test cycle will begin instead when the 3 key is kept press for about one second; during this cycle, the vending machine will carry out a sales cycle in sequence for each gearmotor detected by the self-learning procedure, starting from the current motor up to the last motor of the vending machine.
  • Page 37 Serie "EUR7" > OTOR SELF LEARNING Select this item to repeat the self-learning of the motors present in the vending machine; this action is only allowed if a password is set in the protected parameters menu. Programming Diagnostics Motor Slearning ->->->->...
  • Page 38 Serie "EUR7" > (FTCA) ENDING SENSOR TEST Select this item to test the vending sensor circuit (FTCA). Programming Diagnostics FTCA sens. test ->->->-> Left Nois Righ The following message will appear on the display: Left Nois Righ The “Left” and “Righ” parameters indicate the degree of intensity of the light detected by the sensors. The “Nois”...
  • Page 39: Summary Table

    Serie "EUR7" UMMARY TABLE (*) Memorandum to be filled out after the programming under way Adjusted Default Menu Parameter Meaning Min-Max to (*) General Param’s Language Message language Italian General Param’s LCD contrast LCD contrast setting General Param’s Operating mode Operating mode General Param’s DDD DD/mm hh:mm...
  • Page 40 Serie "EUR7" (*) Memorandum to be filled out after the programming in progress Parameter Meaning Min-Max Adjuste Menu Default d to (*) 0)Single no Chang 1)Single Sale Modalit. MDB MDB parameters MDB sales modes 1)Single+Change Change 2)Multi Vend Coin nn vvvvv MDB parameters Coins present In tubes xxx yyy...
  • Page 41: Eclaration Of Conformity

    Serie "EUR7" EC D ECLARATION OF ONFORMITY Damian S.r.l. Declaration not valid Via Ragazzi del „99 n°30 without the 21053 Castellanza identification plate Varese Italy Tel. +39 0331 322020 Fax +39 0331 322030 Dichiara che la macchina descritta nella targhetta di identificazione è conforme alle disposizioni...
  • Page 42: General Warranty Conditions

    Damian S.r.l. is not responsible for possible injuries and damage to persons or objects caused directly or indirectly by the lack of observance of the instructions given in this manual and of any other information transmitted by the manufacturer to the customer, concerning, above all, the warnings/cautions relative to installation, use and maintenance of the device.
  • Page 43 Serie "EUR7" Rev. M - 01 Pagina A - 25...