Page 1
MP-1000 (110V) Ozone Generator Operating Manual Produced for and Distributed by: A2Z Ozone, Inc 1844 Cargo Court. Louisville, KY 40299 USA 1+502-499-4977 EPA Est.: 95432-KY-1 Active Ingredient: Ozone. Warning: Do Not Inhale Ozone. Keep Out of Reach of Children. Produced by: Bluegrass Water Technology Shenzhen Co., Ltd.
Table of Contents Important Safety Information ................2 Technical Specifications ..................3 Features ........................4 Timer Functions ....................6 Installation Instructions ..................7 Operating Instructions ..................8 Maintenance ......................11 Troubleshooting ....................12 Warranty ........................15 WARNING: Do Not Inhale Ozone. Ozone Can Damage Lungs if Inhaled. Remove Immediately to Fresh Air if exposed.
• Electric shock hazard. Use the power cable provided to connect the MP-1000 to a properly rated and grounded receptacle. • If the MP-1000 will be used where water is present, a ground fault circuit interrupter must protect the circuit.
Features Indicates ozone is functioning. If the LED is illuminated, the unit is Ozone Light working properly. Indicates when there is power to the unit. If the power is supplied, the Power Light light will remain illuminated. Switch Used to control ozone power within the unit. Used to power on the small internal air compressor built into each Air Pump Switch MP Series unit.
Timer Functions The MP-1000 (110V) Ozone Generator is equipped with timer functions. The hourly timer knob can be adjusted between 15 minutes and 4 hours, at any time interval between. • 15 minutes to 4 hours • To operate this timer, turn the knob clockwise to the desired set position.
NOTE: The water tank requires an exhaust to the outside of the building with an ozone destructor to remove excessive ozone. Main Power • Use the power cable provided to connect the MP-1000 to a properly rated and grounded receptacle. • If the MP-1000 will be used where water is present, a ground fault circuit interrupter must protect the circuit.
The dial can be adjusted after starting, but avoid dialing up and down continually, as this action may harm the control board. • Set the unit timer for the desired application duration. • At this point, the MP-1000 is powered up. To turn the unit off: • For Ambient Air: •...
Page 10
• Connect oxygen bottle/tank to ozone generator (Oxygen In Port). • Connect MP-1000 Ozone Generator (Ozone Out Port) to venturi injector. • Install a check valve 10 inches after ozone outlet tube fitting. This can be done by cutting a tube ten inches after ozone outlet fitting.
Page 11
• Prior to shutting off the oxygen generator feed gas to the MP-1000, first turn off the ozone generator switch and allow the unit to purge with oxygen for about 1 minute. • Then, turn off the oxygen generator. Using Internal Air Compressor:...
Changing Fuse The outside fuse is located near the back rocker switch. The ozone board fuse is located on the back left of the board. See the table below for details: Unit Outside Fuse (AMPs) Ozone Board Fuse (AMPs) MP-1000...
Troubleshooting Problem Possible Cause What to Do Normally the fuse on the back of the unit Bad ozone board will blow or the ozone light won’t light up. Contact us for a replacement board. No Ozone Make sure the air loop is in the correct (Ozone LED is not No air flow position if using ambient air.
Page 15
• Turn off ozone generator and let air flow through the unit for five to ten minutes. • Check the fuse, change if needed. • The MP-1000 uses a 3 AMP fuse for the back rocker switch and a 3 AMP fuse in the ozone board.
A2Z Ozone warrants that it or its authorized dealers will repair or replace, at its option, any part of such products proven to be defective in materials or workmanship within ONE (1) year from the date of retail purchase of such products.
Page 17
This information can be also be sent by EMAIL to us. Please provide ALL pertinent information and send within twenty (20) days to: service@a2zozone.com Otherwise, please fill out completely and return to A2Z Ozone by post within twenty (20) days of purchase. Customer Info: Name__________________________________________________________...