A2Z Ozone MP-5000 Operating Manual

A2Z Ozone MP-5000 Operating Manual

(110v) ozone generator

Advertisement

Quick Links

MP-5000 (110V) Ozone
Generator
Produced for and Distributed by:
A2Z Ozone, Inc
1844 Cargo Court.
Louisville, KY 40299 USA
1+502-499-4977
EPA Est.: 95432-KY-1
Active Ingredient: Ozone.
Warning: Do Not Inhale Ozone.
Keep Out of Reach of Children.
Produced by:
Bluegrass Water Technology Shenzhen
Co., Ltd.
Shenzhen, Guangdong 518110
Made in China
EPA Est.: 95432-CHN-1
Version 1.2.2
Operating Manual
*Register your product at
a2zozone.com/pages/warranty

Advertisement

Table of Contents
loading

Summary of Contents for A2Z Ozone MP-5000

  • Page 1 MP-5000 (110V) Ozone Generator Operating Manual Produced for and Distributed by: A2Z Ozone, Inc 1844 Cargo Court. Louisville, KY 40299 USA 1+502-499-4977 EPA Est.: 95432-KY-1 Active Ingredient: Ozone. Warning: Do Not Inhale Ozone. Keep Out of Reach of Children. Produced by: Bluegrass Water Technology Shenzhen Co., Ltd.
  • Page 2: Table Of Contents

    Table of Contents Important Safety Information ..............2 Technical Specifications ................3 Features ...................... 4 Timer Functions ..................6 Installation Instructions ................7 Operating Instructions ................8 Maintenance .....................11 Troubleshooting ..................12 Warranty ....................15 WARNING: Do Not Inhale Ozone. Ozone Can Damage Lungs if Inhaled. Remove Immediately to Fresh Air if exposed.
  • Page 3: Important Safety Information

    ELECTRICAL PRECAUTIONS DURING OPERATION: • Follow all electrical codes. • Turn power off and disconnect from power source before any service work is performed. Failure to do so could result in serious injury or death. • Electric shock hazard. Use the power cable provided to connect the MP-5000 to a properly rated and grounded receptacle. • If the MP-5000 will be used where water is present, a ground fault circuit interrupter must protect the circuit. PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Use ozone test strips or dissolved ozone monitor to acquire your desired level of ozone. CAUTION: In case of accidental leakage, install the ozone generator in a well- ventilated area.
  • Page 4: Technical Specifications

    Technical Specifications Items Included: • MP-5000 (110V) Ozone Generator • MP-5000 (110V) Ozone Generator operation manual • 8 feet of flexible tubing included • 8 feet of PTFE tubing • Two 2” oblong diffuser stones included • Spare fuse included •...
  • Page 5: Features

    Features Indicates ozone is functioning. If the LED is illuminated, the unit is Ozone Light working properly. Indicates when there is power to the unit. If the power is supplied, Power Light the light will remain illuminated. Switch Used to control ozone power within the unit. Air Pump Used to power on the small internal air compressor built into the Switch...
  • Page 6 MP-5000...
  • Page 7: Timer Functions

    • To operate this timer, turn the knob counterclockwise. Note: You can control the MP-5000 (110V) Ozone Generator with a garden timer. Just turn on all switches and position timer to “ON”. Plug the unit to the timer (15 AMP) and set the timer to run the unit.
  • Page 8: Installation Instructions

    Main Power • Use the power cable provided to connect the MP-5000 (110V ) Ozone Generator to a properly rated and grounded receptacle. • If the MP-5000 will be used where water is present, a ground fault circuit...
  • Page 9: Operating Instructions

    • Set the unit timer for the desired application duration. • The timer can be dialed counterclockwise to allow for an “Always On” function. • Keep in mind, this function is not recommended for oxygen air. • At this point, the MP-5000 (110V) Ozone Generator is powered up.
  • Page 10 • Set tank gas flow meter at 2-4 liters per minute and 5 PSI maximum. • First, open the oxygen valve. Then turn on the main ozone power switch on the front panel of the MP-5000. The internal air compressor switch stays OFF. The ozone light and fan should turn on.
  • Page 11 • Increase power to the cells by turning the ozone control knob clockwise. • Prior to shutting off the oxygen generator feed gas to the MP-5000 (110V) Ozone Generator, first turn off the ozone generator switch and allow the unit to purge with oxygen for about 1 minute.
  • Page 12: Maintenance

    Changing Fuse The outside fuse is located near the back rocker switch. The ozone board fuse is located on the back left of the board. See the table below for details: Unit Outside Fuse (AMPs) Ozone Board Fuse (AMPs) MP-5000...
  • Page 13: Troubleshooting

    Troubleshooting Problem Possible Cause What to Do Normally the fuse on the back of the unit will blow or the ozone light won’t Bad ozone board light up. Contact us for a replacement board. No Ozone Make sure the air loop is in the correct (Ozone LED is not position if using ambient air.
  • Page 15 • Turn off ozone generator and let air flow through the unit for five to ten minutes. • Check the fuse, change if needed. • The MP-5000 uses a 3 AMP fuse for the back rocker switch and a 5 AMP fuse in the ozone board.
  • Page 16: Warranty

    A2Z Ozone warrants that it or its authorized dealers will repair or replace, at its option, any part of such products proven to be defective in materials or workmanship within ONE (1) year from the date of retail purchase of such products.
  • Page 17 This information can be also be sent by EMAIL to us. Please provide ALL pertinent information and send within twenty (20) days to: service@a2zozone.com Otherwise, please fill out completely and return to A2Z Ozone by post within twenty (20) days of purchase. Customer Info:...

Table of Contents