CEG ECOJET 500PC Installation And Operating Instruction Manual

CEG ECOJET 500PC Installation And Operating Instruction Manual

Domestic water pump

Advertisement

INSTALLATION AND OPERATING INSTRUCTION MANUAL
ECO
DOMESTIC
WATER PUMP
2
YEAR WARRANTY
ELECTRIC MOTORS AND PUMPS
1
Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may differ slightly from those illustrated and described in this publication.

Advertisement

Table of Contents
loading

Summary of Contents for CEG ECOJET 500PC

  • Page 1 INSTALLATION AND OPERATING INSTRUCTION MANUAL DOMESTIC WATER PUMP YEAR WARRANTY ELECTRIC MOTORS AND PUMPS Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products which may differ slightly from those illustrated and described in this publication.
  • Page 2: Table Of Contents

    GENERAL SUPPLIED WITH PRODUCT PRODUCT DESCRIPTION TECHNICAL DATA DIMENSIONAL DRAWING APPLICATION ENVIRONMENTAL PROTECTION WARRANTY SAFETY GENERAL ELECTRICAL SAFETY PERSONNEL QUALIFICATION ALTERATIONS AND SPARE PART PROCUREMENT ABNORMAL OPERATING CONDITIONS TRANSPORT AND STORAGE INSTALLATION SUCTION GUIDE ELECTRICAL CONNECTION INSTALLATION FOR FLOODED SUCTION INSTALLATION FOR LIFT SUCTION MAINTENANCE OPTIONAL EXTRAS...
  • Page 3: General

    Dear Customer, Congratulations on your purchase of the CEG ECOJET water pump. Like all CEG products, we have developed them with the help of the latest technology and they have been manufactured with the most advanced components. Please check the...
  • Page 4: Product Description

    SolidWorks 2014 SolidWorks 2014 File Name: Ecojet_Series_CAD_left_top.SLD File Name: Ecojet_Series_CAD_right_side.SLD File Description: CEG 3D CAD Water Hydraulic Design File Description: CEG 3D CAD Water Hydraulic Design TECHNICAL DATA Water temperature range min / max 5°C- 40°C Ambient temperature 0°C - 50°C...
  • Page 5: Dimensional Drawing

    The ECOJET cannot be used for sea water, flammable, corrosive, explosive or dangerous liquids!! ENVIRONMENTAL PROTECTION CEG is dedicated to a recovery and recycle service which simplifies the disposal process for end users at the completion of a products life, minimising the environmental impact. CEG is dedicated to minimising its environmental footprint wherever possible and is continuously searching for improved ways to operate.
  • Page 6: Safety

    SAFETY This instruction manual contains basic rules on safety which must be strictly adhered to. The installer and the operator must carefully read these instructions prior to installation and commissioning. Please observe all of the safety directions, not only under the main heading ‘Safety’ but each sub-heading also. Non-observance of safety reference may cause bodily harm to persons or damage to the pump.
  • Page 7: Suction Guide

    lt is the operator’s responsibility to take all preventative measures (e.g. provision of alarm systems, standby pump etc.) To avoid consequential damages such as flooding due to pump failure. In order to ensure proper operation a static discharge head of 300mm is required; the discharge pipe must be installed with a vertical rise of at least 300mm! Frost damage will not be covered under warranty! SUCTION GUIDE...
  • Page 8: Installation For Flooded Suction

    - Electrical plug connections must be made in flood-safe locations and be protected from moisture - Check available power supply - Verify that the voltage and frequency of the ECOJET pump shown on the nameplate corresponds to those available on the supply - Observe local earthing requirements (do not cut off earth pin or use an adapter fitting) - Pumps must only be operated with electrical cables or extension leads up to a maximum of 10 metres Do not use the pump if the power cord or plug are damaged.
  • Page 9: Installation For Lift Suction

    Recommended installation Not recommended installation Tee w/plug Valve Valve Valve Non-return valve Non-return valve Screen Flood suction from tank above ground Flood suction from tank above ground Drawing 4.1 Drawing 4.0 INSTALLATION FOR LIFT SUCTION - Check to ensure that a sufficient water level is available in the supply tank or bore - Ensure that the ECOJET is securely fastened to stop any vibration that may cause slow wear of the pump - Ensure that the pump is unplugged - Ensure suction pipe has non-return valve (provided) fitted to the discharge of the water supply,...
  • Page 10: Maintenance

    Recommended installation Recommended installation valve Valve Drawing 6.0 Non-return valve Non-return valve Screen Screen Drawing 6.0 Suction lift from bore/well Suction lift from stream Drawing 6.1 Recommended installation Not recommended installation Valve Valve Tee w/plug Non-return valve Non-return valve Screen Screen Drawing 6.3 Suction lift from tank below ground...
  • Page 11: Optional Extras

    OPTIONAL EXTRAS 3L PRESSURE TANK The installation of a small 3L pressure tank after the pump and PRESSCONTROL in the system is recommended. This reduces water hammer and pump start and stop cycle, increasing the operating life for your ECOJET and reducing start up wear. By decreasing the pump’s start/stop cycling with a 3L expansion tank, this then helps to decrease the total power consumption significantly.
  • Page 12: Eco-Pure Filter Housing

    ECO-PURE FILTER HOUSING 25mm (1") 25mm (1") Brass Inserts Brass Inserts 10" FILTER HOUSING KIT 10" JUMBO FILTER HOUSING KIT 10" TWIN FILTER HOUSING KIT 20" JUMBO FILTER HOUSING KIT ALL FILTER HOUSING KITS INCLUDE: Appropriate lter, mounting brackets, screws and spanner *10”...
  • Page 13: Eco-Pure Filtration Cartridges

    ECO-PURE FILTRATION CARTRIDGES ECO-PURE POLY SPUN Provide high e ciency ltration for the removal of sediment in water supplies, removing sand, silt, dirt and rust particles. Ideal for: Mains drinking water Rainwater Dam water / Bore water Pretreatment for UV treatment systems Available in 1micron, 5micron, 20micron and 50micron ECO-PURE POLY PLEATED Ideal for removal of sand, silt, dirt and rust particles from drinking...
  • Page 14: Electronic Presscontrol

    ELECTRONIC PRESSCONTROL PC-1100 PRODUCT DESCRIPTION PRESSCONTROL is a device that guarantees optimal control of pumps for domestic use. Deriving from a hydraulic and electronic logics project for the Australian and New Zealand market, it is capable of simultaneously detecting both the pressure and the flow, as well as automatically managing the pump I N T E G R AT E D operation.
  • Page 15: Starting

    STARTING When the unit is connected to the electrical network, the green LED “Power On” lights up and the yellow LED “Pump On” indicates that the pump is in operation. The pump continues to operate for up to 5 seconds enabling the system to fill the pipes and to reach the required pressure.
  • Page 16: Spare Parts

    SPARE PARTS ECOJET 500 STAINLESS STEEL SELF-PRIMING JET PUMP Name Name Plug M10x1.25 Serrated lock washer external teeth Φ4 Washer Washer Φ4 Dust cap Hexagonal nut M4 Inside hexagonal bolt M6x12 Cross recessed pan head tapping Pump housing component screws ST3.5x12 O-Ring d131x3.5 Capacitor 10uF/450V O-Ring d23.8x3.1...
  • Page 17: Ecojet 1000 Stainless Steel Self-Priming Jet Pump

    SPARE PARTS ECOJET 1000 STAINLESS STEEL SELF-PRIMING JET PUMP Name Name Dust cap Bottom part of terminal box Dust proof Cross recessed pan head screw and washer assemblies M4x8 Air drain plug M10x1.25 O-Ring d120x2 Washer Connection pole Inside hexagonal bolt M5x10 Serrated lock washer external Inside hexagonal bolt M5x18 teeth Φ4...
  • Page 18: Ecojet 1500 Stainless Steel Self-Priming Jet Pump

    SPARE PARTS ECOJET 1500 STAINLESS STEEL SELF-PRIMING JET PUMP Name Name Dust cap G2” Bottom part of terminal box Air drain plug M10x1.25 Cross recessed pan head screw and washer assemblies M4x8 Washer d9.2x2.4 O-Ring d120x2 Inside hexagonal bolt M6x12 Connection pole Inside hexagonal bolt M6x18 Serrated lock washer external...
  • Page 19: Faults, Causes And Solutions

    FAULTS, CAUSES AND SOLUTIONS FAULTS CAUSES SOLUTIONS Pump does not Interruption of the power supply, Check power supply short circuit or an insulation fault in Call an expert to check the pump unit the motor coil Pump runs, Pump or pipes are blocked due to Check all filters/check valve for foreign matters but little or no foreign matters...
  • Page 20: Code Of Compliance

    This product has been tested to relevant standard and found compliant with specifi cation: CEG AS/NZ Issue F0054 version A We CEG New Zealand Ltd and CEG Group PTY Ltd declare under our sole responsibility that the product is in conformity with the listed standard or other normative documents.

This manual is also suitable for:

Ecojet 1000pcEcojet 1500pc

Table of Contents