Advertisement

Quick Links

MedViron Rise II Bassinet
Operations & Maintenance Manual
Corporate Headquarters:
9380 Pentatech Drive, Zeeland, MI 49464
Website: medviron.com
Email: customerservice@medviron.com
Toll free: 844.633.8476
(Rev 1 )
984-0061-0000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rise II Bassinet and is the answer not in the manual?

Questions and answers

Summary of Contents for MedViron Rise II Bassinet

  • Page 1 MedViron Rise II Bassinet Operations & Maintenance Manual Corporate Headquarters: 9380 Pentatech Drive, Zeeland, MI 49464 Website: medviron.com Email: customerservice@medviron.com Toll free: 844.633.8476 (Rev 1 ) 984-0061-0000...
  • Page 2: Symbols Used In This Manual

    Contact Information Corporate Headquarters: Email: customerservice@medviron.com Medviron LLC Toll free: 1-844-633-8476 9380 Pentatech Drive Zeeland, Michigan 49464 USA Website: medviron.com Mailing address: Medviron LLC P.O. Box 286 Zeeland, Michigan 49464 USA medviron.com | customerservice@medviron.com | 1-844-633-8476 | 984-0061-0000 (Rev 1 )
  • Page 3: Table Of Contents

    Serial Number Location _____________________________________________________________________________ 9 Manufacturer Contact Information _________________________________________________________________ 9 Safety and Risks ___________________________________________________________________________________ 10 Cleaning Instructions_______________________________________________________________________________ 12 Drawer Liner Removal______________________________________________________________________________13 Preventative Maintenance List _____________________________________________________________________ 14 Service Part List ____________________________________________________________________________________ 15 Warranty ___________________________________________________________________________________________16 medviron.com | customerservice@medviron.com | 1-844-633-8476 | 984-0061-0000 (Rev 1 )
  • Page 4: Bassinet Description

    MedViron Rise II Bassinet Description MedViron Rise II Bassinets have two distinct parts, a plastic tub with mattress which sits on a mobile storage cabinet with drawer and easily adjustable surface height. The bassinet has a pull-out work surface which is accessible from either side. The bassinet’s modern design conveys the warmth of home, while also implying competent, current healthcare.
  • Page 5: Features

    The base panel’s concave curves also allow caregivers to stand closer while caring for the infant. 6. KYDEX thermofilm has been used for impact resistance and durability. ® medviron.com | customerservice@medviron.com | 1-844-633-8476 | 984-0061-0000 (Rev 1 )
  • Page 6: Specifications

    Drawer internal dimensions 22.5in W x 13.25in L x 6in D The bassinet tub or drawer boxes are not intended to be used for bathing. medviron.com | customerservice@medviron.com | 1-844-633-8476 | 984-0061-0000 (Rev 1 )
  • Page 7: Moving The Bassinet

    5. Make certain that the floor is free of obstruction and beware of transitions in the floor. NEVER PUSH THE BASSINET FROM THE FRONT OR REAR. NEVER PULL THE BASSINET BEHIND YOU. TRANSPORT OF AN INFANT MUST OCCUR IN THE LOWEST HEIGHT POSITION ONLY. medviron.com | customerservice@medviron.com | 1-844-633-8476 | 984-0061-0000 (Rev 1 )
  • Page 8: Trendelenberg Positioning

    DO NOT LET GO OF THE TUB UNTIL YOU ARE CERTAIN THE TUB HOOK IS FIRMLY SEATED ON THE RAIL. NEVER PLACE ANY FOREIGN OBJECTS INSIDE OR ON TOP OF THE BASSINET TUB. medviron.com | customerservice@medviron.com | 1-844-633-8476 | 984-0061-0000 (Rev 1 )
  • Page 9: Serial Number Location

    Contact Information Corporate Headquarters: Email: customerservice@medviron.com MedViron LLC Toll free: 1-844-633-8476 9380 Pentatech Drive Zeeland, Michigan 49464 USA Website: medviron.com Mailing address: MedViron LLC P.O. Box 286 Zeeland, Michigan 49464 USA medviron.com | customerservice@medviron.com | 1-844-633-8476 | 984-0061-0000 (Rev 1 )
  • Page 10: Safety And Risks

    THIS IS NECESSARY TO AVOID TIPPING THE BASSINET. NEVER PLACE AN INFANT ON THE PULL-OUT WORK SURFACE. WHEN MOVING THE BASSINET, THE OPERATOR SHOULD PUSH ONLY FROM THE EITHER END USING THE BASSINET HANDLES. medviron.com | customerservice@medviron.com | 1-844-633-8476 | 984-0061-0000 (Rev 1 )
  • Page 11 THE PULL-OUT WORK SURFACE SHOULD BE FULLY CLOSED AND IN THE LOCKED POSITION BEFORE MOVING THE BASSINET. PINCH POINTS EXIST AT THE LOCATIONS INDICATED IN THE DRAWINGS BELOW. PLEASE BE CAREFUL. medviron.com | customerservice@medviron.com | 1-844-633-8476 | 984-0061-0000 (Rev 1 )
  • Page 12: Cleaning Instructions

    MedViron Rise II Bassinet Product Care and Disinfection Clean with a damp cloth or mild detergent solution. MedViron furniture can withstand a wide range of hospital cleaners and disinfectants. When using any of these products, read and follow the manufactures directions carefully. Do not use abrasive or solvent cleaner. A CDC recommended chlorinated bleach solution of 5.25% -6.15% sodium hypochlorite (i.e., household...
  • Page 13: Drawer Liner Removal

    Warning labels must be intact and legible. _____ Check mattress for tears, punctures, or wear. _____ Verify that the pull-out work surface can be secured. Serial number Date PM Completed Completed by medviron.com | customerservice@medviron.com | 1-844-633-8476 | 984-0061-0000 (Rev 1 )
  • Page 14 Stainless Steel Drawer Pull 557-0036-0028 Plastic Drawer Liner 558-0063-0000 Caster Replacement Kit (4 casters w/hardware) 556-0305-0000 Drawer Front 530-M009-Kxxx Please contact your dealer or sales representative to order service parts. medviron.com | customerservice@medviron.com | 1-844-633-8476 | 984-0061-0000 (Rev 1 )
  • Page 15: Service Part List

    In the event a product has to be returned to the factory for verification of a defect and/or repair, it must be pre-approved in writing by MedViron freight pre-paid, and include a copy of the original invoice with the date and name of original purchaser.

Table of Contents