Set Temperature; Using The Device Without Power; Using The Device In A Car (Battery Protection) - MAGIRA ARCTIC DF36-C Operating Instructions Manual

Mobile dual zone fridge
Hide thumbs Also See for ARCTIC DF36-C:
Table of Contents

Advertisement

Available languages

Available languages

3.4 Set Temperature

To set the temperature in the cooling zone, press the
respective temperature controls +/-
14
zone and +/-
for the right cooling zone.
13
14

3.5 Using the Device Without Power

Please ensure an uninterrupted power supply during operation.
The device is not designed for operation without power
supply and can only keep its temperature to a limited time,
depending on the outside temperature.

3.6 Using the Device in a Car (Battery Protection)

The device is equipped with a three-stage battery protection.
To protect your battery, the device switches off when the
battery voltage falls below the respective battery voltage.
Use the High mode if you have connected the device to
your starter battery
Use the Medium mode if you have connected the device
to your starter battery and the conditions are good (e.g. no
severe cold, no severe heat, no long periods of standing)
Use the Low mode only when using separate supply batte-
ries to ensure vehicle starting. If this mode is used when
connected to the starter battery, it may not be possible to
start the vehicle
30
13
for the left cooling
The cooling zones can be set diffe-
rently using the respective tempe-
rature controllers.
Please note that the left cooling
zone can never be colder than the
right cooling zone
Example:
✔ Left: 5°C
Right: − 15°C
✔ Left: 5°C
Right: 5°C
✔ Left: - 15°C
Right: − 15°C
✖ Left: - 15°C
Right: 5°C
Adjustment:
16
Press the SET button
for at least 3 seconds until the
currently set mode (H, M or L) flashes.
16
Then press the SET button
again to switch the desired-
mode.
The corresponding mode will be saved as soon as the letter
stops blinking.
Mode
Low
12 V
PV
8.5
SV
10.9
24 V
PV
21.3
SV
22.7
PV = Protection Value
Undervoltage protection, as soon as this voltage is reached,
the device immediately switches off all consumers and can-
not be switched on again.
SV = Startup Value
If this voltage is dropped below, the compressor will not start
to cool down again. The control remains active until the volta-
ge rises again and the device can operate normally or the vol-
tage drops below the Protection Value (protective shutdown).
EN
Medium
High
10.1
11.1
11.4
12.4
22.3
24.3
23.7
25.7
31

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Arctic df50-c

Table of Contents