C o n t e n t s Safety Specifications Intent of Use Tool Specification Tool Dimensions Putting into Service Principle of Operation Preparation for Use Operating Instructions Nose Assemblies Fitting Instructions for N10 Fitting Instructions for N11 Maintenance Dismantling Instructions Assembling the Tool General Assembly of Installation Tool General Assembly Parts List...
S a f e t y This instruction manual must be read with particular attention to the following safety rules, by any person installing, operating, or servicing this tool. Do not use outside the design intent. Do not use equipment with this tool/machine other than that recommended by Avdel UK Limited. Any modification undertaken by the customer to the tool/machine shall be the customer’s entire responsibility.
S p e c i f i c a t i o n s I n t e n t o f U s e The T10 Installation Tool is basically a Piston and Cylinder Assembly. When coupled Hydraulically and Electrically to a compatible Hydraulic Power Source and the relevant Nose Assembly is attached, it is then used to install 5 to 10 mm Lockbolts in Industrial Environments.
M a i n t e n a n c e IMPORTANT Read the safety rules on page 4 carefully P r i n c i p l e o f O p e r a t i o n When both hoses and control cord are connected to the Hydrapac, the pull and return cycles of the tool are controlled by depressing and releasing the trigger switch located in the handle respectively.
Page 7
IMPORTANT Nose assembly parts must be assembled clean and dry. Do Not lubricate with oil or grease. F i t t i n g I n s t r u c t i o n s N10 for 10 mm ( ") Avdelok ®...
Page 8
IMPORTANT Nose assembly parts must be assembled clean and dry. Do Not lubricate with oil or grease. F i t t i n g I n s t r u c t i o n s N11 for 10 mm ( ") Avbolt ®...
S e r v i c i n g t h e To o l D a i l y • Check for oil leaks. • Check the stroke of tool. • Check for worn anvil indicated by score marks on the installed collar. This can also be confirmed by referring to the installed data in the fastener catalogue.
F a u l t D i a g n o s i s S y m p t o m P o s s i b l e C a u s e R e m e d y P a g e R e f Tool fails to operate Inoperative Hydrapac...
Page 14
F a u l t D i a g n o s i s S y m p t o m P o s s i b l e C a u s e R e m e d y P a g e R e f Jaw segments do not Improper operation of jaw Check internal parts of the...
Page 15
D e c l a r a t i o n o f C o n f o r m i t y We, Avdel UK Limited, Watchmead Industrial Estate, Welwyn Garden City, Herts, AL7 1LY declare under our sole responsibility that the product: Model: T10 Serial No.
Page 16
Tel: +82 31 798 6340 Email: info@acument.com.au Email: AvdelDeutschland@acument.com Fax: +82 31 798 6342 Email: info@acumentkorea.com CANADA ITALY Avdel Canada, a Division of Acument Avdel Italia S.r.l. SPAIN Canada Limited Avdel Spain S.A. Viale Lombardia 51/53 87 Disco Road 20047 Brugherio (MI)