Troubleshooting
You can rectify minor faults on your appliance yourself. Read the troubleshoot-
Troubleshooting
ing information before contacting after-sales service. This will avoid unneces-
sary costs.
WARNING
Risk of electric shock!
Incorrect repairs are dangerous.
Repairs to the appliance should only be carried out by trained specialist
staff.
Only use genuine spare parts when repairing the appliance.
If the power cord of this appliance is damaged, it must be replaced with a
special connection cable, which is available from the manufacturer or his
Customer Service.

Error code / Fault display / Signal

Fault
E:21-30 will light up altern-
ately.
E:21-60 will light up altern-
ately.
E:30-00 will light up altern-
ately.
E:31-00 will light up altern-
ately.
E:34-00 will light up altern-
ately.
E:32-00 will light up altern-
ately or indicator for water
supply lights up.
46
Cause
Intake opening of Zeolith
container is covered by
items of tableware.
Appliance has detected cal-
cified heating element.
Water protection system is
activated.
Water protection system is
activated.
Water is continuously run-
ning into the appliance.
Supply hose is kinked.
Water tap is turned off.
Water tap is jammed or
furred up.
troubleshooting
Re-arrange the tableware in the ap-
pliance so the "Intake opening of
the Zeolith container " → Page 16
is no longer obstructed.
Descale the appliance.
1.
Operate the appliance with the Wa-
2.
ter softening system.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 59.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 59.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 59.
Install the supply hose without
kinks.
Turn on the water tap.
Turn on the water tap.
The flow rate must be at least 10 l/
min when the water supply is open.