Fault Reporting

Fault Reporting
Control boards in this unit store active and historical faults. Each
control board will report active faults continuously and will report the
last four faults stored after a power cycle of the unit. See Fault Table in
the Service Facts for list of fault codes.
The active and historical faults can also be accessed through the Alert
Menu in the Display Assembly.
Clearing Fault History
Option 1:
1.
Scroll to the Alert Menu in the Display Assembly.
2.
Scroll to the Alert History section.
3.
Scroll to the Clear History selection and push the Enter key. At the
"Are You Sure" question, push the Enter again.
Option 2:
1.
Press and hold the Unit Test Button for 10-12 seconds.
2.
Release the Unit Test button and wait 5 seconds.
3.
Cycle 230VAC power to the unit. (the blower panel can be
removed to achieve this)
18-GJ83D1-1C-EN
CLEAR HISTORY?
YES
<ENTER>
51