5.6.
oPerAtIons to Be cArrIed out eVerY 500 hours:
a) replace air filter. (see fig.4)
b) check all tube fittings and electrical connections.
5.7.
recommended oils;
recommended oil for compressors, suitable for room
temperatures ranging from +5°c to +25°c.
seAleY cPo or equivalent sAe 40 compressor oil. room
temperature below +5°c: sAe 20 compressor oil.
Approximate oil capacity: 0.16 litres.
5.8
iMPORtANt WARNiNG - Air contaminants taken into the
compressor will affect optimum performance. example: Body
filler dust or paint overspray will clog the pump intake filter
and may cause internal damage to pump/motor components.
Please note that any parts damaged by any type of
contamination will not be covered by warranty.
5.9
inspection of pressure tank both inside and out.
under the Pressure sYstems sAfetY regulAtIons 2000 it is the responsibility of the owner of the compressor to initiate a
system of inspection that both defines the frequency of the inspection and appoints a person who has specific responsibility for
carrying out the inspection.
6. tROUBLESHOOtiNG
FAULt
1A) Pressure drop in the tank
1B) Pressure drop in the tank
1c) Pressure drop in the tank
2) Pressure switch valve leaks when
compressor is idle
3) Air leaks from tank body or tank welds
4A) motor stops and will not restart
4B) motor stops and will not restart
5) compressor stops and does not restart
6A) compressor does not stop at max. pressure
6B) compressor does not stop at max. pressure
7) compressor noisy with metallic knock
8) excessive moisture in discharged air
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMPORtANt: no liability is accepted for incorrect use of this product.
WARRANtY: guarantee is 12 months from purchase date, proof of which will be required for any claim.
iNFORMAtiON: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
© Jack sealey limited
CAUSE
Air leaks at connections
Air leaks from safety valve
Air leaks from cylinder head gasket
non-return valve seal defective
Internal corrosion caused by infrequent tank
draining or non permitted modifications to tank
thermal cut out has operated
supply fuse has tripped
motor failure
Pressure switch fault
filter clogged
head gasket or valve fault
Bearing or piston damage
high humidity environment
Sole UK distributor, Sealey Group,
Kempson Way, suffolk Business Park,
Bury st. edmunds, suffolk,
IP32 7Ar
Original Language Version
REMEdY
run compressor to max. pressure, switch off.
Brush soap solution over connections and look for
bubbles. tighten connections showing leaks.
If problem persists contact Authorised service Agent
operate the safety valve manually by pulling on the
ring. If valve continues to leak when in the closed
position it should be replaced
check tightness of head bolts. If leak continues
contact authorised service Agent
empty the air tank. referring to fig.6, remove the
non-return valve cap (3), spring (2) and seal (1).
clean the seal and its seat, or if necessary replace
the seal
tank could rupture or explode. cannot be repaired
diSCONtiNUE USE iMMEdiAtELY
Allow unit to cool for 30 minutes before restarting
Press trip reset button (fig.7) and restart unit. If
repeated tripping occurs replace the check valve or
contact authorised service Agent
contact Authorised service Agent
contact Authorised service Agent
replace filter element.
contact Authorised service Agent
contact Authorised service Agent
drain tank after each use