Page 9
30 W 1φAC110V±15% 50/60Hz 1φAC220V±15% 50/60Hz FA-A1 FA-A2 LFA-A1 LFA-A2 LFR-A1 LFR-A2 1.Single phase AC110 or AC220V is 1.此機種使用單相AC110V或單相 applicable to this machine, but if is AC220V,若配接錯誤或所提供的電源錯 誤會造成控制器燒毀。 connected to the wrong power voltage or is supplied with the wrong power, the controller may burn.
Page 10
1φAC110V±15% 50/60Hz 1φAC220V±15% 50/60Hz FA-A1 FA-A2 LFA-A1 LFA-A2 LFR-A1 LFR-A2 單相AC110V或 單相AC220V 電源插座 Single-phase AC110V or AC220V Socket PS.LFR才有配備打帶輪組 (LF290-A2/LF290- A1)。 Only LFR is equipped with the tape attaching wheel(LF290-A2/LF290-A1)。...
Page 11
電源開關 Power switch 送帶長度調整旋鈕 The adjusting knob of feeding the tape Description of the operation of feeding 送帶操作說明: the tape 減少送帶長度 增加送帶長度 Decrease the Increase the length the tape length the tape 圖5/Fig.5...
Page 13
1.送帶馬達無動作: 1.Tape feeding motor doesn’t work: 檢查電源開關是否開啟 開啟檢查電源開關 Check if the power switch. Turn on the power switch. 檢查感應馬達(LF362/FA22Q)電源線,連 接在控制板(LF360/FA24Q) CON7的接 點,是否脫落。 Check if the power cord of the sensor motor(LF362/FA22Q),which is connected to the contact of the control board(LF360/FA24Q)CON7,falls off. 檢查感應器的訊號線(LF263、LF262),連...
Page 14
2.打帶馬達無動作: 2.Tape attaching motor doesn’t work: 檢查送帶拉桿(LF60K-7/FA14K)是否卡 住 Check if the pull rod of the tape feeding(LF60K-7/FA14K)is stuck. 檢查打帶馬達(LF298)/(LF267)之啟動電 容電源線(LF370),連接在控制板 (LF360/FA24Q) CON5的接點是否脫 落。 Check if the power cord of the start capacitor (LF370)of the tape attaching motor(LF298)/(LF267) connected to the contact of the control board (LF360/FA24Q) CON5 loosens.
Need help?
Do you have a question about the FA Series and is the answer not in the manual?
Questions and answers