UNIVERSAL BATTERY CHARGER & MAINTAINER 12V 25 AMP Congratulations on purchasing the Kincrome KP87006 fully automatic switched mode battery charger, power supply, maintainer and rejuvenator. Please take the time to carefully read and understand this manual before using this product.
Fully microprocessor controlled with safety timers at every stage. • Battery condition analysis. • Selectable battery type. • Selectable charge rate / mode. • Patented battery rejuvenation (reconditioning). • Battery Voltage retention analysis. • Pulse charge for long term maintenance. KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1.0.indd 3 18/04/2018 2:15 PM...
Page 4
• Power Supply Mode: Press & Hold the Charge Rate button for 3 seconds to activate and deactivate Power Supply Mode. When in Power Supply Mode, the Power Supply LED will be ON. KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1.0.indd 4 18/04/2018 2:15 PM...
TIMED OUT IF BLUE BULK LED ALSO FLASHING FAST / BULK CHARGING TIMED OUT IF BLUE BULK LED ALSO ON Note: If both the Battery Type and Charge Rate LED’s are flashing, this means the unit is in ECO mode. KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1.0.indd 5 18/04/2018 2:15 PM...
ON. • ECO MODE: This Kincrome Battery Charger has a built in ultra low power consumption circuit. If AC power is connected and the battery is disconnected, after 10 seconds the charger will automatically go into an ECO mode.
WARNING: DO NOT connect the RED (+) lead to the carburettor or fuel lines. BLACK BLACK SEE QR CODE FOR CONNECTION IN VEHICLE CONNECTION IN VEHICLE POSITIVELY EARTHED NEGATIVELY EARTHED QUICK START PRODUCT VIDEO Fig 3 KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1.0.indd 7 18/04/2018 2:15 PM...
Page 8
Bulk Charging - BLUE Bulk LED ON (Charge Voltage depends on battery type selection) Uses the maximum selected charge output until the battery Voltage reaches the Charge Voltage specified for the selected Battery Type. If the battery Voltage doesn’t KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1.0.indd 8 18/04/2018 2:15 PM...
Page 9
(3) Remove the RED (+) lead from the battery. Note: Check electrolyte levels if possible after charging as they may need topping up with distilled water (This does not apply to sealed maintenance free batteries). KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1.0.indd 9 18/04/2018 2:15 PM...
- Output leads are Short Circuited or - Check output connections. Power Supply - Switch off some loads to Power Supply LED Reverse Polarity Mode reduce load current. is ON - Output has been overloaded KP87006 OzCharge_Manual_OC1225U_OC_2412U_V1.0.indd 11 18/04/2018 2:15 PM...
(24 months) commences on the date that the product is purchased. If this product has materials or workmanship defects (other than defects caused by abnormal or non warranted use) you can, at your cost, send the product to place of purchase, an authorised Kincrome service agent or one of Kincromes addresses for repair or replacement.