1
A
P6019
3
A
P61318

PEDESTAL FIXING

The filter pump must be vertically fixed on ground or a certain pedestal made of wood or concrete before use. There should be two
holes 9mm in diameter on the pedestal, the space between which should be 166mm. Put filter pump on the pedestal and fix them
together by fasten the bolts and nuts. All the pedestal parts should weigh over 18kgs at least to prevent the pump from accidentally
falling.
NOTE:
It is important to ensure all elements: Hoses, Debris Screens and Inlet/Outlet Valves are properly aligned.

Operation

1) Open/unscrew the Air Purge Valve (P6112) on the top of the Filter Pump; air is released as water fills the Filter Pump.
Note:
If knob should become dislodged, simply place it back into the hole and turn clockwise to rethread air purge valve.
2) When water comes out of the Air Purge Valve (P6112) screw it closed and wipe away any water.
3) Test the GFCI plug.
NOTE:
It is imperative to check that the hydraulic connectors are not closed.
B
P6019
B
P6680
2
A
A
A
B
B
4
A
2-M8 nut
2-M8 bolt
A
6
B
A
B
B
P6124
A
B
B

Hide quick links: