Prime DS101 Operating Instructions Manual page 2

Double metal detector
Table of Contents

Advertisement

Control Module
The control module allows fast and easy setup and for diagnosis of system errors or problems.
Calibration is achieved through the simple press of a push-button switch. Faults are reported
through different flash patterns on the green and yellow "no double" and "double" indicators.
When the unit first powers up, the two indicators flash alternately as the unit determines which
model of probe is attached. If the probe is not recognized, the flash pattern changes with the
DOUBLE indicator on solid and the NO DOUBLE indicator flashing. When probe assessment
has completed successfully, the indicators stop flashing
Other features of the control module include:
95 to 130 or 200 to 250 volt operation selected through internal jumpers.
Form C relay output providing normally open or normally closed contacts.
LED indicators report the gauge states of NO DOUBLE and DOUBLE.
Automatic setup of system gain and operating parameters.
Simple push-button calibration.
Non-volatile memory that retains all calibration parameters even when power is removed.
Latching relay output that is cleared by asserting the RESET input.
Probe fault detection and reporting via the two front panel indicators.
External Calibrate terminals for convenient placement of the calibrate switch
Metal present output to verify the sheet has fed properly
Probes
The DS101 operates with a several different Prime magnetic probes including Models PM4,
PM10, and PM15. All probes are potted and completely sealed. The probes do not respond to
small amounts of fine metal filings, oil or dirt.
Probe Model
PM4
PM10
PM15
Min thickness
.04 mm (.0015")
.10 mm (.004")
.15 mm (.006")
Max thickness
.40 mm (.015")
1.0 mm (.040")
1.5 mm (.060")
2
Probe Diameter
18 mm (0.70")
30 mm (1.18")
36 mm (1.42")