OPERATING INSTRUCTIONS
Model DS101 DOUBLE SHEET DETECTOR
DESCRIPTION
The Model DS101 Double Metal Sheet Detector comprises a control module in a polycarbonate
housing with a single probe to form a system that detects the thickness of ferrous (magnetically
attracted) metals passing the face of the probe. The detector system may be used on automatic
sheet feeders where double or overlapped sheet material may jam or damage the receiving
machine. A double feed produces an output to stop the machine or signal the operator.
Model DS101
Double Metal
Detector
FUSE
P
RIME
CONTROLS, INC.
NO DOUBLE
DOUBLE
CALIBRATE
®
1
2
March 12, 1999

Advertisement

Table of Contents
loading

Summary of Contents for Prime DS101

  • Page 1 FUSE DESCRIPTION The Model DS101 Double Metal Sheet Detector comprises a control module in a polycarbonate housing with a single probe to form a system that detects the thickness of ferrous (magnetically attracted) metals passing the face of the probe. The detector system may be used on automatic sheet feeders where double or overlapped sheet material may jam or damage the receiving machine.
  • Page 2 Metal present output to verify the sheet has fed properly Probes The DS101 operates with a several different Prime magnetic probes including Models PM4, PM10, and PM15. All probes are potted and completely sealed. The probes do not respond to small amounts of fine metal filings, oil or dirt.
  • Page 3: Installation

    Electrical Wiring All wiring for the DS101 connects to terminal blocks at the bottom of the control circuit board within the enclosure as described in the following paragraphs.
  • Page 4: Inputs And Controls

    DOUBLE indicator goes out and the green NO DOUBLE indicator turns on. Automatic reset is normally selected to control the operation when the fault condition is automatically removed or the DS101 is wired into the stop circuit of a machine with a manual restart circuit.
  • Page 5: Switches And Jumpers

    A two position DIP switch to the right of the terminal blocks controls the selection of the calibration mode and the system response time as described below under CONFIGURATION SWITCHES AND JUMPERS.
  • Page 6 OUTPUTS The DS101 outputs include a form C relay for reporting OVER conditions and a dc logic output for reporting no material in front of the probe. The logic output is labeled the NOTHING output since it provides an indication that nothing is present in front of the probe.
  • Page 7 Normally where double thickness discrimination is required, the DS101 can be calibrated on a single thickness of the material to be monitored (one press of the push button). If finer changes in thickness are to be discriminated, the DS101 may be calibrated on two different thicknesses of the same material.
  • Page 8: Firmware Version

    FIRMWARE VERSION From time to time, as improvements are made to Prime products, the firmware controlling the units is revised. When setting a unit up or troubleshooting it may be necessary to determine the version number for the firmware installed in your unit. The version numbers begin with 1.0 and are incremented either by tenths (1.1, 1.2, etc.) for small revisions or by the integer digit (1.0, 2.0,...
  • Page 9: Specifications

    SPECIFICATIONS Enclosure Material: Polycarbonate Color: Light gray body, clear cover Dimensions: 6.70 in. high x 4.75 in. wide x 2.17 in. deep (170 mm x 121 mm x 55 mm) Seal: Nema 4x Mounting Holes: 0.175 in. diameter on 6.25 in. x 3.58 in rectangle 4.45 mm diameter on 159 mm x 91 mm rectangle Power requirements 95 to 130 volts, 50/60 Hz at 50 mA (Suitcase jumpers A and C installed).
  • Page 10: Troubleshooting

    If the problem is not resolved, call the factory for assistance. For further information or service assistance, contact Prime Controls, Inc., 4551 Gateway Circle, Dayton, Ohio 45440-1711. Phone: (937) 435-8659, Fax: (937) 435-2091. Mention model...
  • Page 11 4.75 (121) 3.575 (91) RIME ® CONTROLS, INC. Model DS101 Double Metal Detector NO DOUBLE DOUBLE CALIBRATE FUSE...
  • Page 12 LIMITATION AND EXCLUSION OF WARRANTIES All goods purchased from Prime Controls, Inc. shall be free from defects in materials, design and workmanship under normal conditions of use for one year from the date of shipment. THIS WARRANTY IS THE SOLE WARRANTY...