Feature (cont.)
If you need to move/replace the outdoor unit or when there are problems on indoor units or on the pipes, outdoor unit will
recover refrigerant remaining on the pipes.
• Through the window on outdoor unit PCB display, you can check the main system data during operation.
• Shortened maintaining and inspection
• Displaying 15 main data including high pressure of system
• - Outdoor temperature
• - Discharge temperature of the compressor
• - Condensing temperature
• Using the DIP switch on the outdoor unit PCB, you can limit the running current of the system
Samsung Electronics
Indoor unit
malfunction
Refrigerant recoveringsss