Power Supply CBA, AV CBA, Front-A CBA & Front-B CBA Bottom View
AV CBA
Not used
Front-B CBA
WF3
WF1
WF1
WF2
WF1
WF4
WF1
C2303
PIN 7 OF
PIN 9 OF
PIN 16 OF
PLUS LEAD
CN2200
CN2200
CN2200
1-11-21
WF5
WF1
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
PIN 24 OF
If Main Fuse (F1001) is blown , check to see that all components in the power supply
CN2200
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
Power Supply
CBA
Front-A CBA
Not used
CAUTION !
F
For continued protection against fire hazard,
replace only with the same type fuse.
A
V
ATTENTION : Pour une protection continue les risqes
d'Incele n'utiliser que des fusible de même type.
Risk of fire-replace fuse as marked.
"This symbol means fast operating fuse."
"Ce symbole reprèsente un fusible à fusion rapide."
Because a hot chassis ground is present in the power supply
circuit, an isolation transformer must be used when repairing.
Also, in order to have the ability to increase the input slowly,
when troubleshooting this type of power supply circuit,
a variable isolation transformer is required.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
BE5SK0F01011