Vent-free gas heater

Advertisement

Quick Links

REM-B300LT-F / REM-B200LT-F / REM-B100LT-F /
REM-B300NT-F / REM-B200NT-F / REM-B100NT-F
WARNING
This appliance
is equipped
for natural or
propane gas. Field
conversion is not
permitted.
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury, or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be provided. Refer to the AIR FOR COMBUSTION
AND VENTILATION section on page 8 of this manual.
This appliance may be installed in an aftermarket, permanently located, manufactured (mobile)
home, where not prohibited by local codes. This appliance is only for use with the type gas indicated
on the rating plate. This appliance is not convertible for use with other gases.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Models:
!
CAUTION —FOR YOUR SAFETY
REM-R150LM-F / REM-R180NM-F
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1636
Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com
VENT-FREE
GAS HEATER
User's Manual and
Operating Instructions
Models:
REM-R280LT-F / REM-R300NT-F /
ANS Z21.11.2-2013
© 2017 Pinnacle Climate Technologies, Inc. REWD-405

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Remington REM-B300LT-F and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pinnacle Climate Remington REM-B300LT-F

  • Page 1 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1636 Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com © 2017 Pinnacle Climate Technologies, Inc. REWD-405...
  • Page 2: Table Of Contents

    Maximum 14 in. W.C. 11 in. W.C. 14 in. W.C. 11 in. W.C. Minimum* 11 in. W.C. 7 in. W.C. 11 in. W.C. 7 in. W.C. *For Purpose of Input Adjustment ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 3: Safety Information

    California to cause cancer, birth defects, or other reproductive harm. This product contains chemicals, including lead and lead compounds, known to the state of California to cause cancer, birth defects, or other reproductive harm. Wash hands after handling. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 4 Operating the heater above elevations of 4,500 feet may cause pilot outage. • To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity. • Provide adequate clearances around air openings. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 5 1. Remove heater and base from the carton. 2. Remove all protective packaging used on the heater. 3. Inspect the items for shipping damage. If you notice any damage, contact the dealer where the heater was purchased. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 6: Product Identification

    FAN KIT (Select models) The fan kit helps to distribute the warmed air into the space more rapidly. NOTE: This is an optional accessory and is not required for operation of the heater. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 7: General Preparation

    Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANS/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 8: Preparing For Installation

    If your residence meets all the above criteria, additional fresh air must be provided. See VENTILATION AIR FROM OUTDOORS on page 10 for more information. If your residence does not meet those three criteria, continue to DETERMINING FRESH-AIR FLOW FOR THE HEATER LOCATION. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 9 C. Install a heater that uses less BTUs/hr if the lower BTUs/hr creates an unconfined space. If the actual BTU/ hr used is less than the maximum BTU/hr the space can support, the space is an unconfined space. In this case, no additional fresh air ventilation is needed. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 10 Attic spaces must have enough fresh air to supply all Attic appliances in both spaces. Crawl Space Crawl Space Inlet Inlet Ventilated Inlet Air Crawl Space Ventilated Inlet Air Crawl Space ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 11: Installation

    Contact the place where this heater was purchased for a heater appropriate for your gas supply. NOTICE: State or local codes may only allow operation of this appliance in a vented configuration. Check your state or local codes. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 12 *A second side wall must be at least 18 in. away from the other side of the heater. Always maintain a minimum of 36 in. clearance from furniture and draperies. *For the installation in residential garages, refer to the CAUTION statement above. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 13 Label all wires prior to disconnection when CAUTION servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Rocker Switch Fig. 7—Operating the Fan Fig. 8—Fan Wiring Diagram Rocker Switch ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 14 4. Once the heater is in place, secure it to the floor using the Support Leg Screws and mounting holes found on the heater Support Legs (See Fig. 10). ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 15 4. Tighten the wood screws until the mounting bracket is firmly fastened to the wall studs. 5. Before mounting the heater, check that the wall bracket is secure. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 16 2. Place the heater onto the mounting bracket. Slide the horizontal slots onto the stand-out tabs on the mounting bracket. Ensure the spacers rest evenly against the wall Fig. 14b—Mounting the Heater (See Fig. 14b). Onto the Mounting Bracket ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 17 Apply pipe joint sealant lightly to the male threads. This prevents excess sealant from going into the pipe. The heater valves may become clogged if excess sealant gets into the pipes. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 18 Fig. 12—Gas Inlet to Regulator to the Equipment Shutoff Valve To Regulator EQUIPMENT SHUTOFF VALVE Flexible Gas Line or Black Pipe to Heater Cabinet Regulator PROPANE/LP To External Regulator NATURAL GAS To Gas Supply ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 19 Fig. 15.1—Checking Gas Joints (Propane/LP Only) Fig. 15.2—Checking Gas Joints (Natural Gas Only) Gas Control Valve Gas Control Valve Equipment Equipment (Behind) (Behind) Shutoff Shutoff Valve Valve Propane/ LP Supply Tank Gas Meter ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 20: Operation

    D. Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 21 When the room temperature drops below the set temperature, the burner will cycle back on. The control knob can be set to the desired comfort level between 1 and 5. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 22 TO TURN OFF GAS TO THE HEATER 1. Turn the control knob clockwise to the “OFF” position. Shutting Off the Burner Only (Pilot Stays Lit): 1. Turn the control knob clockwise to the “PILOT” position. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 23 • See the TROUBLESHOOTING GUIDE, page Fig. 20—Correct Pilot Flame Pattern Fig. 21—Incorrect Pilot Flame Pattern Do not allow fans to blow directly into the heater. Avoid any drafts that alter WARNING burner flame patterns. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 24: Care And Maintenance

    If using compressed air in a can, follow the directions on the can exactly. You may damage the pilot assembly if the directions are not followed exactly. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 25 REM-R150LM-F / REM-R180NM-F Primary Air Primary Air Inlet Hole Primary Air Inlet Hole Primary Air Opening Slot Opening Slot Fig. 25—Pilot Air Inlet Hole Air Inlet Hole Verify proper operation after servicing. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 26: Troubleshooting Guide

    5. Gas regulator setting is incorrect. 5. Replace gas regulator. 6. Control knob not in PILOT position. 6. Turn control knob to PILOT position. 7. Depleted gas supply (propane). 7. Contact local propane/LP gas company. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 27 1. Metal is expanding while heating 1. This is common with most heaters. If noise is just after burner is lit or contracting while cooling. excessive, contact a qualified service technician. or shut off. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 28 B. Connecting, installing, testing, repairing, or servicing equipment and is a.) experienced in such work, b.) familiar with all precautions required, and c.) has complied with all the requirements of the authority having jurisdiction. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 29: Parts List

    Piezo REM-PZO100A Burner REM-BRN400L REM-BRN400N REM-ODS100L REM-ODS100N Regulator REM-FIT300L REM-FIT300N Screen REM-DEC103B Wall Mounting Bracket REM-WALLMT-30 ODS Thermocouple (not shown) REM-PTC100A For replacement parts, contact Pinnacle Climate Technologies at (866) 676-1636. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 30 REM-PZO100A Burner REM-BRN402B REM-ODS100L REM-ODS100N Regulator REM-FIT200L REM-FIT200N Screen REM-DEC103B Glass REM-DEC130A Wall Mounting Bracket REM-WALLMT-30 ODS Thermocouple (not shown) REM-PTC100A For replacement parts, contact Pinnacle Climate Technologies at (866) 676-1636. ©2017 Pinnacle Climate Technologies Vent-Free Gas Heater User’s Manual...
  • Page 31: Limited Warranty

    Limited Warranty Pinnacle Climate Technologies, Inc. warrants this If Pinnacle Climate Technologies, Inc. finds the item appliance to the original retail purchaser only, to be free to be in normal operating condition, or not defective from defects in material and workmanship for a period the item will be returned freight collect.