REM-L240ALT-F / REM-L240ANT-F / REM-L240CLR-F / REM-L240CNR-F
WARNING
This appliance
is equipped
for natural or
propane gas. Field
conversion is not
permitted.
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury, or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be provided. Refer to the AIR FOR COMBUSTION
AND VENTILATION section on page 8 of this manual.
This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home,
where not prohibited by local codes. This appliance is only for use with the type gas indicated on the rating
plate. This appliance is not convertible for use with other gases.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Models:
REM-L180ALT-F / REM-L180ANT-F
!
CAUTION —FOR YOUR SAFETY
Fax: 320-251-2922 • Web: www.pinnacleclimate.com • Email: info@pinnacleclimate.com
VENT-FREE GAS
LOG HEATER
User's Manual and
Operating Instructions
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1636
© 2017 Pinnacle Climate Technologies, Inc. REWB-401
ANS Z21.11.2-2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Remington REM-L180ALT-F and is the answer not in the manual?

Questions and answers

Summary of Contents for Pinnacle Climate Remington REM-L180ALT-F

  • Page 1 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1636 Fax: 320-251-2922 • Web: www.pinnacleclimate.com • Email: info@pinnacleclimate.com © 2017 Pinnacle Climate Technologies, Inc. REWB-401...
  • Page 2: Table Of Contents

    7 in. W.C. 14 in. W.C. 7 in. W.C. 14 in. W.C. Minimum* 6 in. W.C. 11 in. W.C. 6 in. W.C. 11 in. W.C. 6 in. W.C. 11 in. W.C. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 3: Safety Information

    This product contains chemicals, including lead and lead compounds, known to the state of California to cause cancer, birth defects, or other reproductive harm. Wash hands after handling. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 4 • Connecting, installing, testing, repairing, or servicing equipment; is experienced in such work; is familiar with all precautions required; and has complied with all the requirements of the authority having jurisdiction. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 5: Product Identification

    The control automatically cycles the burner on and off to maintain a desired room temperature (see page 23). When used as a vented decorative appliance, use of the thermostat function is prohibited. Operate manually only. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 6: General Preparation

    Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANS/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 7: Preparing For Installation

    If your residence meets all the above criteria, additional fresh air must be provided. See VENTILATION AIR FROM OUTDOORS on page 9 for more information. If your residence does not meet those three criteria, continue to DETERMINING FRESH-AIR FLOW FOR THE HEATER LOCATION. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 8 C. Install a heater that uses less BTUs/hr if the lower BTUs/hr creates an unconfined space. If the actual BTU/ hr used is less than the maximum BTU/hr the space can support, the space is an unconfined space. In this case, no additional fresh air ventilation is needed. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 9 Attic appliances in both spaces. Crawl Space Crawl Space Inlet Inlet Ventilated Inlet Air Crawl Space Ventilated Inlet Air Crawl Space ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User’s Manual...
  • Page 10: Installation

    Installing the heater next to vinyl or cloth wall coverings, or operating the appliance where impurities in the air exist (tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.), may cause walls to discolor. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 11 Seal any fresh air vents or ash clean-out doors located on the floor or wall of the fireplace WARNING with a heat-resistant sealant—this prevents drafting caused by pilot outage or sooting. Do not seal the chimney flue damper. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 12 See Fig. 3 and 4 above for minimum clearance requirements. IMPORTANT: If the minimum clearances are not met, you must operate the heater with the chimney flue damper open. See INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION, page 14. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 13 NOTICE: If your installation does not meet the minimum clearances, you must only operate the heater with the flue damper open, or you must raise the mantel to an adequate height. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 14 There are three reasons for operating your heater as a vented model: 1. The fireplace does not meet the clearance requirements for vent-free operation. 2. State or local codes do not permit vent-free operation. 3. You prefer vented operation. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 15 2. Remove all protective packaging used on the logs and heater. 3. Inspect the items for shipping damage. If you notice any damage, contact the dealer where the heater was purchased. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 16 Apply pipe joint sealant lightly to the male threads. This prevents excess sealant from going into the pipe. The heater valves may become clogged if excess sealant gets into the pipes. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 17 Fig. 12—Gas Inlet to Regulator to the Equipment Shutoff Valve To Regulator EQUIPMENT SHUTOFF VALVE Flexible Gas Line or Black Pipe to Heater Cabinet Regulator PROPANE/LP To External Regulator NATURAL GAS To Gas Supply ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 18 Fig. 15.1—Checking Gas Joints (Propane/LP Only) Fig. 15.2—Checking Gas Joints (Natural Gas Only) Gas Control Valve Gas Control Valve Equipment Equipment Shutoff Shutoff Valve Valve Propane/ LP Supply Tank Gas Meter ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 19 • Anchor the grate/burner assembly to the floor using four (4) concrete attachment screws (not included) (see Fig. 16). 1/4" x 3/4" Concrete Hex Head Fig. 16—Mounting Locations Flanged Attachment Screws ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 20: Log Placement

    #1, 2, and 3. Place log #7 so on logs #1and 2. Place log #7 so logs #2 and 3. it’s resting on logs #1 and 2. it’s resting on logs #1, 2, and 3. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 21 4. Place log #4 so that it’s resting grate base, making sure it’s on logs #1 and 2. Place log #5 so aligned with logs #1 and 2. that it’s resting on logs #1, 2, and 3. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 22: Operation

    D. Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 23 When the room temperature drops below the set temperature, the unit will cycle back on. The control knob can be set to the desired comfort level between 1 and 5. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 24 1. Set the thermostat to the lowest setting. 2. Press the “OFF” button on the remote control. 3. Push in slightly and turn the control knob clockwise to the “OFF” position. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 25 Do not allow fans to blow directly into the heater. Avoid any drafts that alter WARNING burner flame patterns. Do not use a blower insert, heat exchanger insert, or other accessory not WARNING approved for use with this heater. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 26: Remote Control Operation

    Turns the heater ON. Manually operated solenoid ON. Turns the heater OFF. Manually operated solenoid OFF. MODE Changes the heater from manual mode to thermo mode. Sets the temperature in thermo mode. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 27 (3) seconds, the LCD screen defaults to display the Screen while Screen after room temperature and the word “TEMP” shows on the pressing the the 3-Second screen. OFF key Default ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 28 The electronics in the remote control system can power two types of DC-powered components. The receiver is programmed to provide pulse DC voltage (5.5 VDC to 6.3 VDC) to a latching solenoid. If you experience any problems when operating the remote control system, contact Pinnacle Climate Technologies’ customer service. Remote Receiver: IMPORTANT: Do not position the receiver where ambient Fig.
  • Page 29: Installation Instructions

    NOTE: Up to 6.3 VDC of power is provided at the receiver terminal. Red Wire ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 30: General Information

    The security code matching procedure uses a timing function. If the security code is not matched on the first attempt, wait 1–2 minutes and try again, which allows the timer to reset. Follow this procedure 2–3 times if necessary. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 31: Troubleshooting

    FCC REQUIREMENTS THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 32: Care And Maintenance

    FOR VENTED APPLICATIONS Periodic examination and cleaning of the venting system and the solid fuel-burning fireplace, including frequency of such examination and cleaning, must be done by a qualified agency. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 33 If any of the original wire as supplied with the appliance must be replaced, it must be replaced with a wire of at least a temperature rating. Verify proper operation after servicing. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 34: Troubleshooting Guide

    5. Gas regulator setting is incorrect. 5. Replace gas regulator. 6. Control knob not in PILOT position. 6. Turn control knob to PILOT position. 7. Depleted gas supply (propane). 7. Contact local propane/LP gas company. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 35 1. Metal is expanding while heating 1. This is common with most heaters. If noise is just after burner is lit or contracting while cooling. excessive, contact a qualified service technician. or shut off. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 36: Qualified Installing Agency

    B. Connecting, installing, testing, repairing, or servicing equipment and is a.) experienced in such work, b.) familiar with all precautions required, and c.) has complied with all the requirements of the authority having jurisdiction. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 37: Parts List

    Log 1 REM-LOG181A-F Log 2 REM-LOG182A-F Log 3 REM-LOG183A-F Log 4 REM-LOG184A-F Log 5 REM-LOG1845A-F Log 6 REM-LOG186A-F Log 7 REM-LOG187A-F For replacement parts, contact Pinnacle Climate Technologies at (866) 676-1636. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 38 Log 1 REM-LOG241A-F Log 2 REM-LOG242A-F Log 3 REM-LOG243A-F Log 4 REM-LOG244A-F Log 5 REM-LOG2445A-F Log 6 REM-LOG246A-F Log 7 REM-LOG247A-F For replacement parts, contact Pinnacle Climate Technologies at (866) 676-1636. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 39 REM-RRC100A Log Set (Complete) REM-SET240C-F Log 1 REM-LOG243C-F Log 2 REM-LOG244C-F Log 3 REM-LOG245C-F Log 4 REM-LOG246C-F Log 5 REM-LOG247C-F For replacement parts, contact Pinnacle Climate Technologies at (866) 676-1636. ©2017 Pinnacle Climate Technologies Vent-Free Gas Log Heater User Manual...
  • Page 40: Limited Warranty

    Limited Warranty Pinnacle Climate Technologies, Inc. warrants this If Pinnacle Climate Technologies, Inc. finds the item appliance to the original retail purchaser only, to be free to be in normal operating condition, or not defective from defects in material and workmanship for a period the item will be returned freight collect.