Technical Information; Electrical Connection - Haier HOR54B7MSW1 User Manual

Free standing cooker
Table of Contents

Advertisement

TECHNICAL INFORMATION

HOR54B7MSW1
TYPE
Dimensions
90/54/60
(height/width/depth) cm
Cooktop
180mm Hilight heater(kW)
1.8
145mm Hilight heater(kW)
1.2
Oven
Guide levels
5
0.85
Top heater(kW)
1.15
Bottom heater(kW)
1.1
Grill heater(kW)
Oven illumination(W)
25
Function modes
Oven light(W)
25
Top+bottom heater(kW)
2.0
Top heater(kW)
Bottom heater(kW)
1.15
2.0
Top+bottom heater+fan(kW)
Top/grill+Fan(kW)
2.0
Fan(W)
30
Fan+Rear heater(kW)
2.0
Fan+Half grill(kW)
1.1
Fan+Bottom heater(kW)
Temperature
50-250℃
Frequency(Hz)
50
220-240V/380-415V
Electrical Input(V)
3N ~50Hz
Top Oven Power(kW)
2.0
Main Oven Power(kW)
2.0
Hotplate power(kW)
6.0
10.0
Total connected power(kW)
Complies with AS/NZS regulations EN 50304, AS/NZS60335-1,AS/NZS60335-2-6
standards.
21

ELECTRICAL CONNECTION

Caution!
All electrical work should be carried out by a suitably qualified and authorized electrician.
No alterations or willful changes in the electricity supply should be carried out.
The fixing line connected must be equipped with the all-pole disconnection device
provided by breakaway the contact under overvoltage category III according to the
wiring rules.
Fitting guidelines
The cooker is manufactured to work with three phase alternating current (380-415V 3N~50
Hz). The voltage rating of the cooker heating elements is 220-240V. Adapting the cooker
to operate with one phase current is possible by appropriate bridging in the connection
box according to the connection diagram below. The connection diagram is also found on
the cover of the connection box. Remember that the connection wire should match the
connection type and the power rating of the cooker.
CONNECTION DIAGRAM
Caution! Voltage of heating elements 220-240V
Caution! In the event of any connection the safety
Wire must be connected to the
E terminal.
For 220-240V earthed one-phase connecti-
1
on,
bridges connect 1-2-3
terminals and
4-5 terminals, safety wire to
.
For 380-415/220-240V earthed three-phase
2
connection, bridges connect 4-5 terminals,
phases in succession 1,2 and 3, earth to
4-5, the safety wire to
.
L1=R, L2=s, L3=T, N=null terminal, E=safety wire terminal
The connection cable must be secured in a strain-relief clamp.For the connection leads,
the grounding wire must be longer than the other wires.
Caution!
Remember to connect the safety circuit to the connection box terminal marked with
Before connecting the cooker to the power supply it is important to read the informatIion
on the data plate and the connection diagram.
1
2
3
Recommended
type of
connection
4
lead
L1
H05VV-F3G4
E
N
L1
L1
L2
L3
H05VV-F5G1,5
E
N N
22
.