gledhill Torrent GreenHeat TGH140-OV Design, Installation & Servicing Instructions

Torrent greenheat series
Hide thumbs Also See for Torrent GreenHeat TGH140-OV:

Advertisement

Torrent GreenHeat
Open vented thermal store providing heating and mains pressure hot water
Design, Installation & Servicing Instructions
Models covered in this manual
Torrent GreenHeat OV TGH140-TGH350
Torrent GreenHeat SP TGH140-TGH350
Torrent GreenHeat SOL TGH210-TGH450
Torrent GreenHeat HP TGH170-TGH450
Torrent GreenHeat HPSOL TGH210-TGH450

Advertisement

Table of Contents
loading

Summary of Contents for gledhill Torrent GreenHeat TGH140-OV

  • Page 1 Torrent GreenHeat Open vented thermal store providing heating and mains pressure hot water Design, Installation & Servicing Instructions Models covered in this manual Torrent GreenHeat OV TGH140-TGH350 Torrent GreenHeat SP TGH140-TGH350 Torrent GreenHeat SOL TGH210-TGH450 Torrent GreenHeat HP TGH170-TGH450 Torrent GreenHeat HPSOL TGH210-TGH450...
  • Page 2 All goods are sold subject to our Conditions of Sale which are set out at the rear of this specifi cation. In the interest of continuously improving the Torrent range, Gledhill Building Products Limited reserve the right to modify the product without notice, and in these circumstances this booklet, which is accurate at the time of printing, should be disregarded.
  • Page 3 B at the rear of this manual. Maintenance Modifi cations should not be made to this product. Replacement parts, including immersion heaters, should be purchased from Gledhill Building Products Limited, or agents approved by them. The manual must always be left with the Torrent. Note: The cylinder is factory fi...
  • Page 4 DESIGN Gledhill developed the principal of domestic thermal stores starting in 1982 and g) Less controls – The thermal store is open they have been manufacturing them since then. vented and therefore does not require additional safety devices such as temperature Their importance to plumbing systems is described below.
  • Page 5 DESIGN arrangements should be made to power the lower immersion element in order to to the auxiliary heating circuit. However, if a minimise the running costs. It is important to note that the design heat loss, of the low carbon or renewable electricity source is rooms to be heated, must be less than the lowest immersion power.
  • Page 6: Technical Information

    DESIGN Torrent GreenHeat OV Torrent GreenHeat SP Technical litres Torrent GreenHeat OV TGH140-OV 1219 1040 1040 TGH170-OV 1449 1270 1270 TGH210-OV 1414 1235 1235 TGH250-OV 1654 1475 1475 TGH350-OV 1874 1140 1690 1690 Torrent GreenHeat SP TGH140-SP 1219 1040 1040 TGH170-SP 1449 1270 1270...
  • Page 7 3. All connections are within 145˚, but if more detail is required, please contact our technical desk on 01253 474584 or your local Gledhill depot. litres/ litres kWh litres 1040 1115 1.81...
  • Page 8 DESIGN Torrent GreenHeat HP Technical litres Torrent GreenHeat HP TGH170-HP 1449 1270 1270 TGH210-HP 1414 1235 1235 TGH250-HP 1654 1475 1475 TGH350-HP 1874 1140 1690 1690 TGH450-HP 1764 1490 1490 Torrent GreenHeat HP SOL TGH210-HPSOL 1414 1235 1235 TGH250-HPSOL 1654 1085 1475 1475 1000 TGH350-HPSOL 1874...
  • Page 9 3. All connections are within 145˚, but if more detail is required, please contact our technical desk on 01253 474584 or your local Gledhill depot. 4. The domestic hot water volume and maximum hot water flow rate fi...
  • Page 10: System Design

    DESIGN Torrent GreenHeat OV Basic Appliance 1. Open vent - 22mm comp 2. Overheat stat 3. Plate heat exchanger fl ow - 22mm 4. Domestic hot water store sensor 5. Immersion heater 6. Solid fuel fl ow - 28mm comp 7.
  • Page 11 DESIGN Torrent GreenHeat SOL Basic Appliance 1. Open vent - 22mm comp (450 - 28mm comp) 2. Overheat stat 3. Plate heat exchanger fl ow - 22mm 4. Domestic hot water store sensor 5. Solar sensor 6. Solid fuel fl ow - 28mm comp 7.
  • Page 12 DESIGN Torrent GreenHeat HP Basic Appliance 1. Open vent - 22mm comp (450 - 28mm comp) 2. Store overheat 3. Plate heat exchanger fl ow - 22mm 4. Domestic hot water store sensor 5. Hot water supply - 22mm comp 6.
  • Page 13 DESIGN General Heat Pump Sizing • All Torrent GreenHeat HP models covered by this manual, are only suitable for open • The effi ciency (i.e. coeffi cient of performance, vented primary (heat pump and space heating) circuits. Therefore the pressure COP) of an air source heat pump and hence in the primary circuit depends upon the height of the feed and expansion cistern its heat output generally decreases as...
  • Page 14: Installation

    INSTALLATION Model Selection Torrent GreenHeat OV Model Selection Guide Max hot water demand Bedrooms Model The suggested model sizes shown in the tables opposite are based on a typical daily hot water 1 bathroom 1 - 2 TGH140-OV usage and on the assumptions that the heating 1 bathroom + en-suite shower 2 - 4 TGH170-OV...
  • Page 15 INSTALLATION Mains Water Supply Taps and Shower Fittings A typical arrangement of the hot and cold water system is shown below. All Torrent Aerated taps are recommended to prevent models are designed to be fed directly from the mains and they fulfi l the requirements splashing.
  • Page 16 INSTALLATION Pipe Layout water circuit of combination boilers to reduce the rate of accumulation of scale”. To comply In all mains pressure installations it is important to remember that the incoming cold with this requirement: - supply must be shared between all terminal fi ttings. It is important that a 22mm supply is brought to the appliance and a 22mm take-off is continued at least to the bath.
  • Page 17 C1: Store sensor – S6 they must be isolated from the mains before the cover is removed on every occasion. Replacement immersion heaters should be obtained from Gledhill Building Products Limited. Wiring The Control Panel The control panel requires a separate 3 amp fuse spur double pole to ensure safe isolation.
  • Page 18 INSTALLATION Boiler Size Allowance for domestic hot water for sizing the boiler Allowance for domestic The minimum total boiler power required is the hot water heating (kW) Torrent model sum of the power required for space heating which should be calculated in accordance with Full divert mode Flow share mode BS 5449 and the power required for producing...
  • Page 19 INSTALLATION Open vented heating systems 2 Pump System The open vented primary system is fi lled via the feed and expansion (F&E) tank fi tted with the Min. 250mm Torrent OV model and therefore it is important that the F&E tank is positioned at least 250mm above the highest point in the system.
  • Page 20 INSTALLATION The two diagrams shown on this page show S Plan Open Vented Heating System how an ‘S’ plan and ‘Y’ plan may be used in conjunction with the Torrent GreenHeat OV, with another space heating supply being taken Min. 250mm Auxiliary direct from the store.
  • Page 21 INSTALLATION Sealed heating system S Plan Sealed Main Heating System All Torrent SP models are suitable for sealed heating systems up to 3.5 bar maximum Min. operating pressure, however the normal 250mm pressure relief valve setting is 3.0 bar. The typical layout of the open vented ‘Y Plan’...
  • Page 22 INSTALLATION Torrent Green HP Models HP Model With Central Heating From Heat Pump The Torrent GreenHeat HP models are all open vented and are designed to be heated directly by an air or a ground source heat pump which does not require a minimum pressure in the Min.
  • Page 23 INSTALLATION Torrent GreenHeat HP-Solar Models HP SOL Model With Central Heating From Heat Pump The heat pump and space heating system confi gurations and operation with the Torrent Solar GreenHeat HP-solar models is the same as for controller standard models. The solar thermal system Solar pumping station operates independent of the heat pump system.
  • Page 24 INSTALLATION Solar heating circuit S Plan Open Vented Heating System Including Solar Input The Torrent SOL is an advanced thermal store and has been designed to incorporate existing Solar boiler and central heating controls and is based controller on the tried and tested standard Torrent range. Solar pumping station Therefore general design requirements for Pressure...
  • Page 25 INSTALLATION For maximising the use of the renewable ‘green’ energy, the system should be managed and controlled so that unnecessary fi ring of the boiler is kept to a minimum. This can be achieved by a combination of householder use of the system and controls, for example; Use the store to provide shower or a bath to utilise the heat gained by the system from the previous day’s solar energy input.
  • Page 26 INSTALLATION To ensure that the solid fuel boiler does not Gravity Flow Solid Fuel Boiler Pipe Layout overheat the thermal store during its operation and prevent gravity circulation cooling the thermal store when it is not, the following Feed and expansion tank sized to include controls can be used.
  • Page 27 INSTALLATION WIRING DIAGRAMS Page 27...
  • Page 28: Wiring Diagrams

    INSTALLATION CH & HW Programmer Normally Open Pipe Thermostat 2 Room Thermostat 2 Port Valve Junction Local double pole isolator Normally Closed boiler pump Pipe Thermostat 1 2 Port Valve Boiler wiring terminals Mains supply Boiler pump Central heatin 230VAC ~ 5 Amp pump Torrent GreenHeat with 2 pump heating control system and typical solar heating system WIRING DIAGRAMS...
  • Page 29 INSTALLATION Store stat Solar panels Solar controller 230Vac 50Hz Solar supply Pump L N E Torrent GreenHeat SOL Solar pumping station Boiler hold off pipe thermostat Type LL641B1012 Temperature range: 50 – 95 S1 : Solar flow temperature sensor S2 : Solar zone store temperature sensor Overheat S3 : Store overheat temperature sensor/Thermostat thermostat...
  • Page 30: Wiring Diagram

    INSTALLATION CH & HW Programmer Normally Open Pipe Thermostat 2 Room Thermostat 2 Port Valve Junction Local double pole isolator Normally Closed boiler pump Pipe Thermostat 1 2 Port Valve Boiler wiring terminals Mains supply System pump 230VAC ~ 5 Amp 3-Po Flow shar Torrent GreenHeat with ‘Y’...
  • Page 31 INSTALLATION Store stat Solar panels Solar controller 230Vac 50Hz Solar supply Pump L N E Torrent GreehHeat SOL Solar pumping station Boiler hold off pipe thermostat Type LL641B1012 Temperature range: 50 – 95 S1 : Solar flow temperature sensor S2 : Solar zone store temperature sensor Overheat S3 : Store overheat temperature sensor/Thermostat thermostat...
  • Page 32 INSTALLATION CH & HW Programmer Normally Open Room thermostat Pipe Thermostat 2 2 Port Valve Junction box Local double pole isolator Normally Closed Pipe Thermostat 1 2 Port Valve boiler pump Boiler wiring terminals Central heatin Mains supply Zone valve System pump 230VAC ~ 5 Amp Torrent GreenHeat with ‘S’...
  • Page 33 INSTALLATION Store stat Solar panels Solar controller N R1 N R1 N 12 13 14 15 16 17 18 19 20 Torrent GreenHeat SOL Solar pumping station Boiler hold off pipe thermostat Type LL641B1012 Temperature range: 50 – 95 S1 : Solar flow temperature sensor S2 : Solar zone store temperature sensor S3 : Store overheat temperature sensor/Thermostat NOTE...
  • Page 34 INSTALLATION Typical schematic wiring diagram for the Torrent GreenHeat HP and Torrent GreenHeat HP-solar with space heating supplied from thermal store. WIRING DIAGRAM Page 34...
  • Page 35 INSTALLATION Typical schematic wiring diagram for the Torrent GreenHeat HP and Torrent GreenHeat HP-solar with space heating supplied directly from the heat pump circuit. WIRING DIAGRAM Page 35...
  • Page 36 INSTALLATION Typical schematic wiring diagram and system confi guration for the Torrent GreenHeat HP-solar. WIRING DIAGRAM Page 36...
  • Page 37 INSTALLATION Boost Immersion Heater Control By Programmer All Torrent GreenHeat HP models are fi tted with a 3kW immersion heater so that the The operation of the boost immersion heater store can be heated to a temperature above the heat pump delivery temperature to can be controlled by means of an independent increase the hot water performance of the unit if necessary.
  • Page 38 INSTALLATION Torrent OV Models (heated by electricity only) If it is proposed to ‘powerflush’ the heating system we would recommend that the Torrent Ensure that the thermal store is fi lled with water to the water level mark inside the is isolated from the heating system being feed and expansion tank and the ball valve (if fi...
  • Page 39: Important Do's And Dont's

    INSTALLATION DO - Check the incoming mains water pressure. If it exceeds 5.0 bar at any point in the 24 hour cycle then a pressure limiting valve set at 3.0 bar should be fi tted where the cold supply enters the property. DO - Check the fl...
  • Page 40: Servicing And Maintenance

    Free of charge replacements for any faulty components are available from Gledhill during the in-warranty period on return of the faulty part (normally 12 months). After this, spares can be obtained direct from Gledhill Spares, or through any of the larger plumbers merchants/specialist heating spares suppliers.
  • Page 41: Fault Finding

    SERVICING AND MAINTENANCE UNSATISFACTORY Is the power supply Follow the HOT WATER to the PHE controller Switch it on fault finding PERFORMANCE switched on chart Is the model Is the boiler Change for suitable for the thermostat larger model hot water set to max? requirement? Is the boiler...
  • Page 42 SERVICING AND MAINTENANCE The Torrent GreenHeat printed circuit control board/display has been designed to Fault Condition Possible Causes be fully automatic whilst able to provide functional and diagnostic information to the householder/installer. - Thermal store is cold/DHW pump is permanently stuck - Temperature sensor or The board works in conjunction with a number of sensors (thermistors) located as DHW temperature...
  • Page 43 SERVICING AND MAINTENANCE Normal - standby state Indicate system status 2 digit display Press S2 2 push buttons S2 S1 Press Press Press Press Sensor temperature Main reading processor Press S2 Press Press Press Press Control set-point reading Press S2 Press Press Press...
  • Page 44 SERVICING AND MAINTENANCE If a sensor error is detected one of the following S6 sensor (top) Off peak supply DHW pump on three error codes flash alternately with the calling present sensor number instead of the temperature On peak heater E1 Open circuit E2 Short circuit On peak supply...
  • Page 45: Short Parts List

    SERVICING AND MAINTENANCE Description Supplier & Model Part Number Stock Code PHE pump Grundfos, UPR 15-50 5950543 GT089 Plate heat exchanger (PHE) SWEP, 24 Plate heat exchanger E8T/24 GT017 Plate heat exchanger (PHE) SWEP, 30 Plate heat exchanger E8T/30 GT528 Pump isolating valve - outlet 22mm 7308123 XB121...
  • Page 46 APPENDIX Water Savings Water Related Costs Can Be Reduced By Good Plumbing Practice 2 tap 5, 6 or half open Over 8 l/m 20 l/m Fitted with regulator Unregulated TAPS & MIXERS 4 Fixing Options For Taps & Mixers 1. MK Range - Combined Regulators & Aerator for screwing onto Taps &...
  • Page 47 Make sure you and This assessment will cover the largest unit within each product range manufactured any others helping know the route by Gledhill. you intend to take that it is clear of any obstructions. Never jerk the load as this will add a little extra force and For specific weights and dimensions please refer to technical data section.
  • Page 48 BENCHMARK Page 48...
  • Page 49 BENCHMARK Page 49...
  • Page 50: Terms And Conditions

    AMD. NOVEMBER 2012 CONDITIONS OF SALE & GUARANTEE TERMS Gledhill (Building Products) Ltd (“We” or “Gledhills”) only do business upon the Conditions which appear below (i) free of all charge during the first year after delivery and no other. Unless we so agree in writing these Conditions shall apply in full to any supply of goods by us to the by us.
  • Page 51 (2) above. We shall Gledhill have a policy of continuous product development not be responsible for and the Purchaser will indemnify us against liability in respect of damage caused to and may introduce product modifications from time to time.
  • Page 52 BSI Due to a programme of continuous improvement Gledhill Building Products reserve the right to modify products without prior notice. It is advisable to check the product technical detail by using the latest design and installation manuals available from our technical support team or on our website.