Air Supply; Installation - Sunex Tools 90045 Operating Instruction

1.7mm gravity feed spray gun & cup
Table of Contents

Advertisement

90045_op man_041003
4/18/03
Length of Pipe (ft.)
Air Flow
CFM
50
100
10
1/2"
3/4"
20
3/4"
3/4"
30
3/4"
3/4"
40
1"
1"
50
1"
1"
70
1"
1"
Never mount oil and water extractor on or near the air compressor.
During compression, air temperature is greatly increased. As the air cools down to room temperature, moisture
condenses in the air line, on its way to the spray gun. Therefore, always mount the oil and water extractor at a point in
the air supply system where the compressed air temperature is lowest.
Drain air lines properly.
Pitch all air lines back towards the compressor so that condensed moisture will flow back into the air receiver where
it can be drained off. Each low point in an air line acts as a water trap. Such points should be fitted with an easily
accessible drain. See diagram above.
This spray gun is rugged in construction, and is built to yield exceptional value. The life of this product and the efficiency
of its operation depend upon a knowledge of its construction, use and maintenance.
Gravity
Feed
Cup
1:59 PM
Page 3

AIR SUPPLY

150
200
3/4"
3/4"
3/4"
1"
1"
1"
1"
1"
1"
1-1/4"
1-1/4"

INSTALLATION

Fluid
Control
Screw
Air Inlet
Atomization
Pressure Gauge
Oil and Water
Extractor
Air Hose
Pitch pipe back toward air receiver
Compressor Unit
Drain
Oil and Water Extractor should be at least 25 ft. from the compressor, farther if possible.
GRAVITY FEED CUP HOOKUP
Air pressure for atomization is regulated at
extractor. Amount of fluid is adjusted by
fluid control screw on gun, viscosity of
paint, and air pressure.
3
Install drain at
each low point
Oil & Water
Extractor
Drain
25 Feet or
More
Rev. 04/10/03