TROUBLE SHOOTING GUIDE
No power
(LED indicator off)
Check 24V, 12V, 5,2V
of Power B/D
Pass
Check Output of
IC701, IC702, IC704,Q705
IC701, IC702, IC704,Q705
Pass
Check LED Assy
Pass
Check P201 Connector
Copyright © 2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
[A] PROCESS
:
Fail
Fail
Check short of IC701, IC702, IC704
Change IC701, IC702, IC704
Fail
Check short of Main B/D
or Change Power B/D
Pass
Change LED Assy
Fail
Re-soldering or Change defect
Part.
Part