Major Component Specifications - Sanyo SA–93AH Technical & Service Manual

Window type air conditioner
Table of Contents

Advertisement

2-2. Major Component Specifications

Model
SA– 93AH
Controller PCB
Part No.
Controls
Control circuit fuse
Remote Control Unit
Compressor
Type
Compressor model
Source
Nominal output
Compressor oil ... Amount
Coil resistance (Ambient temp. 25°C)
Safety devices
Run capacitor
Fan & Fan Motor
Type
Dia. / Depth
Fan motor model ... Q'ty
Source
No. of poles ... rpm (240 V, High)
Nominal output
Coil resistance (Ambient temp. 20°C)
Safety devices
Run capacitor
Heat Exch. Coil
Coil
Rows
Fin pitch
Face area
External Finish
Type
Overload relay
Operating temp.
Open
Close
Operating amp.(Ambient temp. 25°C)
Type
Operating temp.
Open
Close
W
cc
ATMOS M60 or SUNISO 4GDID ... 350
°C
°C
µF
VAC
Indoor
Centrifugal
mm
ø180 / D85
W
YEL-RED(PNK) : 119
°C
°C
µF
VAC
Evaporator
3
mm
1.4
0.070
m
2
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
3
Rotary (Hermetic)
2P17C225AND
240V Single phase 50Hz
920
C–R : 3.61
C–S : 4.97
External protector
MRA98776
Automatic opening
Automatic reclosing
25
400
ø285 / D90.7
YSK45-4A/K ... 1
240V Single phase 50Hz
4 ... 1,100
40
WHT-BRN : 212
WHT-VLT : 52
VLT-YEL : 13
Thermal protector
135
Automatic reclosing
3.5
440
Condenser
Outdoor
Propeller
3
1.8
0.115

Advertisement

Table of Contents