Access the Product
Controls on the Live View Page
Manual Trigger
The Manual Trigger is used to trigger an action rule from the Live View page. The manual trigger can for example be used to
validate actions during product installation and configuration.
To configure the manual trigger:
1. Go to Setup > Events.
2. Click Add to add a new action rule.
3. From the Trigger drop-down list, select Input Signal.
4. From the second drop-down list, select Manual Trigger.
5. Select the desired action and configure the other settings as required.
For more information about action rules, see Events on page 39.
To show the manual trigger buttons in the Live View page:
1. Go to Setup > Live View Config.
2. Under Action Buttons, select Show manual trigger button.
Click the View size buttons to show the image in full size (right button) or to scale down the image to
fit the browser window (left button).
Click WDR on to enable WDR in intense backlight conditions. Click WDR off to disable WDR in low
light conditions for optimal exposure.
Select a stream profile for the Live View page from the Stream Profile drop-down list. For information
about how to configure stream profiles, see page 19.
Click Pulse to activate the product's output port for a defined period of time. For information about how
to enable and configure output buttons, see page 27. The output button name may differ depending on
the name entered in the I/O Ports configuration.
Click the Active/Inactive buttons to manually activate and inactive the product's output port. For
information about how to enable and configure output buttons, see page 27.
The Manual Trigger button is used to trigger an action rule from the Live View page. For information
about how to configure and enable the button, see Manual Trigger on page 11 .
Click Snapshot to save a snapshot of the video image. This button is primarily intended for use when
the AXIS Media Control viewer toolbar is not available. Enable this button from Live View Config >
Action Buttons.
The product's heater is controlled by the ambient temperature and is turned on and off automatically.
If required, the heater can be activated manually by clicking the Heater button. To show the button,
go to Setup > Live View Config. Under Action Buttons, select Show heater button and specify the
number of minutes the heater should be activated.