5. TROUBLESHOOTING

a. No picture after applying power – (i) check all plugs and cables are securely
connected to the proper connectors; (ii) ensure your power supply is providing the
correct voltage and current.
b. The picture has ripples – (i) check to see if the power supply is experiencing AC ripple,
if so a filter may be required; (ii) determine if the monitor is faulty; (iii) determine if
other peripheral equipment is causing ripple and if so make the necessary
adjustments.
c. The picture background continuously changes color – a fluorescent lamp's magnetic
field may cause color roll, therefore, reduce the number of fluorescent lamps or
increase the distance between the camera and the lamps.
d. The picture appears smeared – (i) the power supply voltage level may be unstable,
therefore, try another power supply; (ii) ensure the cables are correctly connected
and/or the cables are of the correct impedance.
e. Other interference may require a Securitytronix ground loop isolation filter.
f.
Additional troubleshooting assistance can be found on-line at
in addition to support from Securitytronix sales engineers at 1-610-429-1511.
Disclaimer: Consult all regulatory laws regarding hidden & covert video and audio
recording. It is solely the buyer's responsibility, not the seller, to ascertain and obey all
applicable local, state, and federal laws regarding the possession and use of any item
offered by Securitytronix. By placing an order, the buyer represents that all products
purchased will be used in a lawful manner and that he/she is of legal age.