Control Board Adjustments - Linear GSLG-A Installation Manual

Hide thumbs Also See for GSLG-A:
Table of Contents

Advertisement

GSLG-A OPERATOR INSTALLATION GUIDE
LIMIT SWITCH
L.E.D.s
LIMIT SWITCH
CONNECTOR
TERMINAL STRIP #1
CONNECTOR
3A Fuse
2A Fuse
TERMINAL STRIP #2
CONNECTOR
NOTE: DO NOT FORCE 270-DEGREE POTENTIOMETERS
BEYOND THEIR NORMAL RANGE OF MOTION
OR DAMAGE MAY RESULT!
Auto Close Timer Adjustment: This 270-degree adjustable potentiometer will signal the operator to close automatically,
provided no open, reversing or obstruction signals are present from the fully-open position. This timer is adjustable from 0
to 124 seconds. This feature is turned on or off using dip switch #1.
Maximum Run Timer Adjustment: This 270-degree adjustable potentiometer will signal the operator to stop running once
it counts down, unless a limit switch is reached or an input is received fi rst. Each time the motor starts, this timer will begin
counting. This timer is adjustable from 15 to 100 seconds. If the timer expires, the unit locks out and the emergency alarm
sounds.
Open Direction Current Sense Adjustment: This multi turn potentiometer is used to calibrate the built-in current sensing
feature for detection of obstructions while running in the open direction.
Close Direction Current Sense Adjustment: This multi turn potentiometer is used to calibrate the built in current sensing
feature for detection of obstructions while running in the closed direction.
Master/Slave Connection Block: This terminal block is used in conjunction with two operators to confi gure two gates to
open and close together.
Dip Switches:
#1
This switch turns the auto close timer off/on.
#2
This switch is used in conjunction with alarms and fl ashing lights that may be added to the operator. When the switch
is in the ON position, these devices will start approximately two seconds prior to the operator starting. In the OFF
position, the devices will only work while the operator is running.
#3
This switch is used in conjunction with single-button controls and radio receivers. In the ON position, successive inputs
will cause signals in the order of OPEN-STOP-CLOSE-STOP. In the OFF position, inputs will cause an OPEN signal
unless the gate is fully open, in which case it will signal CLOSE.
#4
This switch determines right-hand vs. left-hand behavior. When looking from inside the protected area toward the gate,
the side of the drive the operator is on determines its hand of operation. In the OFF position, the operator is set for
right-hand.
#5
When turned ON, this switch will allow a one-second delay for solenoid locks to unlock before the motor starts.
#6
In the ON position the reverse delay is three (3) seconds. In the OFF position the reverse delay is one and a half (1
1/2) seconds.
#7
Not used at this time.
#8
This switch is used to set Master/Slave confi guration. Operators which are stand-alone or master units should be set
to OFF, while only slave units should have this switch set to ON.

CONTROL BOARD ADJUSTMENTS

DIAGNOSTIC
L.E.D.s
- 9 -