Page 1
GSLG-A Slide Gate Operator Installation Guide Operator models contained in this manual conform to UL325 standard for use in Class I, II, III, and IV applications USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800) 468-1340...
Page 2
FCC Notice ..........27 Model GSLG-A Exploded View .......28 Single Phase Controller Parts List .
If any pages are missing or are unreadable, four single family dwellings with a common garage or parking area or you do not have the safety instructions, please call Linear at associated with these dwellings. 1-800-333-1717 to request additional copies.
Wiring Specifi cations MODEL GSLG-A SINGLE PHASE POWER WIRING MAXIMUM DISTANCE (FEET) VOLTS & HP WIRE GAUGE Refer to the following steps for details on power and SINGLE DUAL accessory wiring for the operator. 115 VOLTS WARNING 1/2-HP ALL AC ELECTRICAL CONNECTIONS TO THE POWER SOURCE AND...
Plate Installation contact with the moving parts of the gate or ground. 72” Figure 2. Post Mounting Specifi cations - 3 - GSLG-A Slide Gate Operator Installation Guide P1222 Revision X5 6-22-2011...
MAY APPEAR DIFFERENT DEPENDING ON THE SLIDE OPERATOR MODEL REMOVE THE BREATHER PIN INSTALL THE VENT PLUG (IF NOT ALREADY INSTALLED) Figure 5. Vent Plug Installation Figure 4. Chain Path - 4 - GSLG-A Slide Gate Operator Installation Guide P1222 Revision X5 6-22-2011...
Page 7
PUSH TO RIGHT TO AC Power Connection RE-ENGAGE OPERATOR All Linear gate operators are supplied with a power disconnect switch to turn on and off the power available to the operator (see Figure 6). Following wiring specifi cations TO MANUALLY MOVE THE GATE,...
Page 8
TO INCREASE TORQUE during normal operation. See Figure 10. LESS TURN ADJUSTMENT NUT To adjust the torque limiter in model GSLG-A: CLOCKWISE ONE FLAT THEN RE-TEST 1. Loosen the setscrew in the adjustment nut. 2. To increase the output, turn the adjustment nut clockwise...
STROBE LIGHT) FOR ACTIVATION (OR DEACTIVATION) DURING GATE OPERATION. N.C. 24 VOLT SOLAR PANEL NOT USED WITH THIS MODEL OPERATOR 24 VOLT BATTERY NOT USED WITH THIS MODEL OPERATOR - 9 - GSLG-A Slide Gate Operator Installation Guide P1222 Revision X5 6-22-2011...
PRESS UP OR 1 TO 59 SECONDS DOWN TO CYCLE THROUGH OPTIONS SET TIMER VALUE PRESS ENTER TO 1 TO 9 MINUTES SELECT AN OPTION AUTO CLOSE TIMER - 11 - GSLG-A Slide Gate Operator Installation Guide P1222 Revision X5 6-22-2011...
(50-75 lbs.) will activate a reversal should an obstruction occur, but high enough to keep the gate moving under normal conditions without interruption. - 12 - GSLG-A Slide Gate Operator Installation Guide P1222 Revision X5 6-22-2011...
SET STAGGER DELAY VALUE 1 TO 99 SECONDS PRESS UP OR DOWN TO CYCLE THROUGH OPTIONS STAGGER DUAL GATES PRESS ENTER TO SELECT AN OPTION DELAY TIME ONLY - 13 - GSLG-A Slide Gate Operator Installation Guide P1222 Revision X5 6-22-2011...
Page 16
OPEN INHIBIT ON, SHADOW LOOP INHIBITS OPENING AND CLOSING PRESS UP OR DOWN TO CYCLE THROUGH OPTIONS SHADOW LOOP PRESS ENTER TO SELECT AN OPTION OPEN PREVENTION - 14 - GSLG-A Slide Gate Operator Installation Guide P1222 Revision X5 6-22-2011...
DOWN TO CYCLE antenna. If using a remote antenna, connect coax cable from the antenna THROUGH OPTIONS to the ANTENNA connector. RADIO PRESS ENTER TO SELECT AN OPTION ENABLE - 15 - GSLG-A Slide Gate Operator Installation Guide P1222 Revision X5 6-22-2011...
Page 18
SELECT AN OPTION DO NOT SELECT OR MOTOR TYPE. NOT USED IN THIS MODEL RESET TO MOTOR TYPE DO NOT SELECT FACTORY DEFAULTS SELECTION NOT USED IN THIS MODEL - 16 - GSLG-A Slide Gate Operator Installation Guide P1222 Revision X5 6-22-2011...
While the gate is opening or closing, the number of seconds obstruction input is cleared, the gate will close when the running time is displayed. auto close timer expires. - 24 - GSLG-A Slide Gate Operator Installation Guide P1222 Revision X5 6-22-2011...
Maximum Run Time has been exceeded, the sounder will beep twice every fi ve seconds. The next operation of the gate will clear the indication. - 25 - GSLG-A Slide Gate Operator Installation Guide P1222 Revision X5 6-22-2011...
How to Order Replacement Parts Use the part numbers listed on the following pages. Contact your local Linear dealer or distributor to order parts. 1. Supply the model number and serial number of your operator. 2. Specify the quantity of pieces needed and order by part number and name of part.
General 2. For operators with V-belts, inspect for wear and replace Linear gate operators are designed for many years of as necessary. Check for proper tension and adjust if trouble-free operation and, under recommended operating required. Check all pulley setscrews for tightness and conditions, will require only minimal maintenance.
By signing this installation checklist, I/we hereby certify that each item listed and checked above has been covered by the installer and is clearly understood by the customer. Customer’s Signature Date Installer’s Signature Date - 32 - GSLG-A Slide Gate Operator Installation Guide P1222 Revision X5 6-22-2011...