h. Blower will run for 90 seconds before beginning the
call for heat again.
i. Furnace should ignite normally.

Checklist

1. Put away tools and instruments. Clean up debris.
2. Verify that the jumper is removed from the TEST/TWIN
terminal. Verify that there is nothing plugged into the PLT
connector.
NOTE: If there is a jumper connector plugged into PLT, remove
it and discard. (See Figure 4)
3. Verify that the Blower/Heat Off Delay jumpers are set as
desired. (See Figure 4 and Figure 15)
Table 5
COOLING AIR DELIVERY - CFM (with filter
RETURN-AIR
SPEED
UNIT
CONNECTION
SIZE
0401410
SIDE/BOTTOM
Orange
0401712
SIDE/BOTTOM
0601412
SIDE/BOTTOM
Orange
0601716
SIDE/BOTTOM
Orange
0801716
SIDE/BOTTOM
BOTTOM or
Orange
0802120
3,4
TWO-SIDES
1002116
SIDE/BOTTOM
Yellow
BOTTOM or
Orange
1002122
3,4
TWO-SIDES
BOTTOM or
1202422
3,4
TWO-SIDES
Orange
NOTE:
1. A filter is required for each return−air inlet. Airflow performance includes a 3/4 in. (19 mm) washable filter media such as contained in factory−authorized accessory
filter rack. See accessory list. To determine airflow performance without this filter, assume an additional 0.1 in. w.c. available external static pressure.
2. Blower speed taps are not always in the same order. Factory Default blower connections are as follows:
Heating airflow − BLUE (also used for Continuous Fan)
Cooling airflow − BLACK (enabled when the Y terminal is energized)
ADJUST THE BLOWER SPEED TAPS AS NECESSARY FOR THE PROPER AIR TEMPERATURE RISE FOR EACH INSTALLATION.
3. Airflows over 1800 CFM require bottom return, two−side return, or bottom and side return. A minimum filter size of 20" x 25" (508 x 635 mm) is required.
4. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return.
5. Highlighted areas indicate that this airflow range is beyond the range allowed for heating. THESE AIRFLOW RANGES MAY ONLY BE USED FOR COOLING.
6. All airflows that are shown in BOLD exceed 0.58 Watts per CFM at the given external static pressure.
12
EXTERNAL STATIC PRESSURE (in.w.c.)
TAPS
0.1
0.2
2
Black
1160
1120
Blue
970
940
Yellow
920
890
Red
730
705
Black
1310
1255
Yellow
1215
1165
1065
1030
Blue
1005
980
Red
750
740
Black
1295
1265
Blue
1035
1010
Yellow
965
940
Red
760
735
5
Black
1760
1705
Yellow
1415
1400
1065
1060
Blue
1010
1000
Red
770
745
Black
1800
1770
Yellow
1445
1430
1250
1240
Blue
1090
1080
Red
880
860
5
Black
2310
2235
Yellow
1720
1700
1515
1500
Blue
1150
1135
Red
945
915
Black
1725
1700
Blue
1500
1475
1235
1215
5
Red
1035
1005
5
Black
2690
2595
Yellow
2180
2145
1790
1795
Blue
1640
1640
Red
1365
1360
Black
2645
2545
Blue
2430
2355
Yellow
1850
1825
1610
1595
Red
1445
1430
5
Specifications subject to change without notice.
4. Verify that the blower (lower door in upflow position) and
control ("Main" or upper door in upflow position) doors
are properly installed.
5. Verify that the Status LED glows. If not, check that the
power supply is energized and that the blower door is
secure. See Figure 14 to interpret diagnostic codes
6. Cycle test furnace with room thermostat to be sure that it
operates properly with the room thermostat. Check all
modes including Heat, Cool and Fan.
7. Check operation of accessories per manufacturer's
instructions.
8. Review Home Owner's Information with owner.
9. Attach entire literature packet to furnace.
)
1
0.3
0.4
0.5
1070
1020
965
905
865
825
855
820
770
670
630
580
1205
1150
1100
1120
1070
1025
1000
960
920
950
920
880
720
700
670
1230
1195
1155
980
940
905
915
885
855
705
675
630
1635
1575
1505
1365
1335
1290
1050
1035
1010
990
975
955
730
710
685
1735
1685
1630
1410
1385
1350
1225
1200
1170
1060
1035
1010
835
810
780
2140
2050
1960
1670
1625
1570
1480
1445
1405
1105
1080
1050
885
860
835
1665
1620
1570
1450
1410
1370
1190
1160
1120
955
915
875
2490
2390
2280
2095
2045
1980
1785
1765
1735
1635
1620
1595
1360
1345
1330
2445
2340
2230
2275
2185
2090
1795
1760
1705
1575
1550
1500
1405
1380
1350
Gas Furnace: N9MSB
0.6
0.7
0.8
905
835
765
770
715
655
720
665
600
535
495
445
1045
985
930
970
915
860
875
830
780
840
790
745
640
615
585
1110
1055
990
865
805
740
805
750
685
570
520
470
1430
1355
1270
1240
1180
1115
975
940
890
925
885
845
660
625
585
1570
1495
1415
1305
1255
1195
1130
1090
1040
970
930
885
750
710
665
1860
1755
1650
1505
1435
1360
1350
1290
1225
1020
980
935
805
770
720
1510
1445
1365
1330
1260
1180
1075
1020
950
825
770
715
2170
2050
1930
1905
1820
1725
1690
1630
1555
1565
1510
1450
1300
1265
1215
2110
1990
1810
1980
1850
1700
1625
1540
1465
1455
1405
1345
1315
1265
1215
440 04 4412 00
.
0.9
1.0
695
630
585
515
545
465
380
335
870
805
800
740
725
670
695
640
550
500
895
795
655
580
610
530
405
335
1180
1090
1040
965
835
770
785
720
545
500
1330
1230
1120
1045
975
910
835
765
615
560
1535
1430
1275
1185
1155
1075
880
815
670
610
1265
1160
1095
1010
880
805
650
575
1810
1675
1615
1490
1460
1350
1365
1270
1155
1080
1685
1580
1600
1500
1380
1280
1270
1185
1150
1075

Advertisement

Table of Contents
loading

Table of Contents