Air Connection; Troubleshooting - Jet JNS-7033 Operating And Maintenance Instructions Manual

1/4-inch air die grinder
Table of Contents

Advertisement

4. When you are finished operating the die
grinder, before storing it disconnect the air
hose and place 4 or 5 drops of air tool oil
into the air inlet; re-connect the air and run
the tool for a few seconds to distribute the
oil.
5. Avoid storing the grinder in very humid
locations which promotes rusting of internal
mechanisms, and always oil it before
storage.

Air Connection

1. Make sure that the air compressor supplies
clean air at the correct CFM for the die
grinder.
2. Set air pressure to 90 psi.

Troubleshooting

Trouble
Die Grinder does not
operate at normal
speed; or speed
remains constant as
trigger is pressed.
Stops operating.
Torque is diminished.
Starts immediately as
soon as air is
connected without
trigger being pressed.
Abnormal vibration
and/or excessive
heat develops in the
tool.
Probable Cause
Air pressure is too low.
Air lines are twisted, or there is a
blockage in them.
Air compressor is malfunctioning, or is
not sufficient capacity for the tool.
Air regulator is malfunctioning.
No air pressure.
Trigger or throttle valve is
malfunctioning.
Air leakage.
Throttle valve or trigger are
malfunctioning.
Improper lubrication.
Excess air pressure and/or
unclean air will shorten the tool's life and
may create a hazardous situation.
3. Drain the water from the air compressor tank
daily, as well as any condensation from the
air lines. Water in the air line may enter the
tool and cause damage.
4. Change filters on the air system on a regular
basis.
5. Air line pressure should be increased
accordingly to compensate for extra long air
hoses (usually over 25 feet). Inside diameter
of the hose should be a minimum of 3/8".
Remedy
Adjust air pressure to 90psi.
Untwist or clean out air lines.
Replace air compressor.
Have regulator repaired or replaced at
an authorized service center.
Check air compressor and hoses.
Make sure compressor is set at 90psi,
and air lines are not twisted.
Have throttle valve/trigger inspected
and repaired at an authorized service
center.
Check connections at the air inlet, o-
rings, etc. Make adjustments/repairs
as needed.
Inspect and repair throttle valve
and/or trigger.
Lubricate properly according to
instructions in this manual.
6

Advertisement

Table of Contents
loading

Table of Contents