Summary of Contents for Glen Dimplex 900GC - AU SS
Page 2
The manufacturer shall not be held responsible for any damages to persons or property caused by incorrect installation or use of the appliance. MODEL: 900GC - AU SS The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors;...
Page 3
DESCRIPTION OF THE HOT PLATES MODEL: 900GC - AU SS U-LPG 1 Wok burner 15.0 MJ 11.9 MJ 2 Rapid gas burner 12.0 MJ 10.8 MJ 3 Semi rapid gas burner (front and rear) 7.3 MJ 6.3 MJ 4 Auxiliary gas burner 4.0 MJ...
Page 4
1) BURNERS - Always place a lid on the pans. - Use only pan with a flat bottom and in thick metal. A diagram is screen-printed above each knob on the front panel. This diagram indicates to which burner the knob in question corresponds. After having Burners Power ratings Pan Ø...
Page 5
Notes: Use of a gas cooking appliance produces heat and moisture in the room in which it is installed. The room must therefore be well ventilated by keeping the natural air vents clear (fig. 3) and by activating the mechanical aeration device (suction hood or electric fan fig. 4 and fig. 5). Intensive and lengthy use of the appliance may require additional ventilation.
Page 6
CLEANING IMPORTANT: Always disconnect the appliance from the gas and electricity mains before carrying out any cleaning operation. 2) HOT PLATE Periodically wash the hot plate, the enamelled steel pan support, the enamelled burner caps “C” and the burner heads “T” (see fig. 6) with lukewarm soapy water. Following this, all parts should be thoroughly rinsed and dried.
INSTALLATION TECHNICAL INFORMATION 3) INSTALLING THE HOT PLATE INSTALLATION PERSONNEL Check that the appliance is in a good condition after having removed the outer packaging and internal This appliance shall be installed only by authorised wrappings from around the various loose parts. In case of persons and in accordance with the manufacturer's doubt, do not use the appliance and contact qualified installation instructions, local gas fitting regulations,...
Page 8
INSTALLATION 4) FIXING THE HOT PLATE IMPORTANT INFORMATION FOR THE The hot plate has a special seal which prevents INSTALLER liquid from infiltrating into the cabinet. Strictly comply When installing the device, the installer must use the with the following instructions in order to correctly supplied fixing brackets according to the scheme apply this seal: - Detach the seals from their backing, checking that...
INSTALLATION 5) GAS CONNECTION Natural Gas Natural Gas installations require the connection of a The gas connection is located in the rear and on the gas regulator at the appliance. This regulator is underside of the appliance 118 mm (for EF/60), supplied with the appliance on purchase.
INSTALLATION 6) ELECTRICAL CONNECTION THE APPLIANCE MUST BE EARTHED Ensure that this power point is properly earthed. The appliance is supplied with a 1800 mm long Look at the connection wiring diagrams flexible supply lead. (fig. 13). The point of attachment for this lead is located at the Warning: In order to avoid any hazard, any rear and on the underside of the appliance electrical work performed on this equipment or...
Page 11
ADJUSTMENTS Always disconnect the appliance from the 7) TAPS electricity main before making any adjustments. Our taps are suitable for all the gas, they are male All seals must be replaced by the technician at conical type at one way. the end of any adjustments or regulations.
Page 12
7. Connect the gas supply to the Regulator. 8. Check for gas leaks. Do not use a naked flame 900GC - AU SS 5 Burners to check for gas leaks. 9. Adjust the gas pressure to 1.00 kPa.
Page 13
6. Remove the Natural Gas Regulator from the models: appliance. 7. Fit the U-LPG test point inlet fitting supplied in 900GC - AU SS 5 Burners the conversion kit. 8. Connect the gas supply to the inlet fitting. 1. Remove each burner cap and burner skirt.
Page 14
CONVERSIONS BURNER ARRANGEMENT ON THE HOT PLATE Table for 900GC - AU SS models NORMAL INJECTOR NOMINAL HEAT BURNERS PRESSURE DIAMETER INPUT (MJ/h) N° DESCRIPTION (kPa) (1/100 mm) MAX. U-LPG 2.75 0.94 11.9 ULTRA RAPID NATURAL 1.00 1.76 15.0 U-LPG 2.75...
SERVICING WARNING: Greasing the taps (see fig. 20 - 21) Servicing should be carried out only by If a tap becomes stiff to operate, it must be authorised personnel. immediately greased in compliance with the following instructions: 10) COMPONENTS REPLACEMENT - Remove the tap.
Page 16
SERVICING CABLE TYPES AND SECTIONS TYPE OF TYPE OF SINGLE - PHASE HOT PLATE CABLE POWER SUPPLY H05 RR - F Section 3 X 0.75 mm Gas hot plate ATTENTION!!! If the power supply cable is replaced, the installer should leave the ground wire longer than the phase conductors (fig.
Should you wish to take out extended warranty, please fill in the details on the leaflet and post this off to: Glen Dimplex Australia, Unit 2, 205 Abbotts Road Dandenong South Victoria 3175...
Need help?
Do you have a question about the 900GC - AU SS and is the answer not in the manual?
Questions and answers