4.2.
COUPLINGS
Vibration may cause failure if a quick change coupling is connected directly to the wrench. To overcome this, connect a leader hose to
the wrench. A quick change coupling may then be used to connect the leader hose to the air line recoil hose (See Figs.1 and 2).
4.3.
HANDLE
Mount the handle by screwing it into the boss on the side of the body.
Fig.1
5. OPERATION
WARNING! Ensure you read, understand and apply safety instructions before use.
5.1.
Only use impact sockets which are specifically designed for use with an impact wrench.
5.2.
Connect the impact wrench to the air hose as in Section 4.
5.3.
Place the socket over the nut or bolt and depress the trigger to operate the wrench.
5.4.
To change direction use the dial located on the rear, this also controls the power of the wrench.
DO NOT use any additional force upon the wrench in order to remove a nut or bolt.
DO NOT allow wrench to free run for an extended period of time as this will reduce bearing life.
6. MAINTENANCE
WARNING! Disconnect impact wrench from air supply before changing accessories, servicing or performing maintenance. Replace or
repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
6.1.
If the air system does not have an oiler, lubricate the impact wrench daily with a few drops of Sealey air tool oil dripped into the air inlet.
6.2.
Clean the wrench after use.
6.3.
DO NOT use worn or damaged sockets.
6.4.
Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose connectors. To remedy check the
air supply and follow instructions in section 4.
b) Grit or gum deposits in the wrench may also reduce performance. If your model has an air strainer (located in the area of the air
inlet), remove the strainer and clean it. Flush the impact wrench out with gum solvent oil or an equal mixture of SAE No 10 oil and
paraffin. Allow to dry before use.
6.5.
For a full service contact your local Sealey service agent.
6.6.
When not in use, disconnect from air supply, clean impact wrench and store in a safe, dry, childproof location.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain off any fluids (if applicable) into approved containers and dispose of the product and the
NOTE: It is our policy to improve products continually and as such we reserve the right to alter data, specifications and component parts without
prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
GSA6005
Environmental Protection
fluids according to local regulation
Fig.2