Press Hotkey button to switch between Color Palette, area
measurement rectangle, temperature limits, and long press
Hotkey button to turn on/off laser sight.
15. Sound Alarm Buzzer
Signal sound alarm when reaches temperature limit.

4. Quick Start Reference

4.1 Infrared Image

1.
Insert Li-Ion battery correctly.
2.
Long press Power button until LED light is on and wait until
system finishes initialization.
3.
Remove IR Lens lid if closed, point to target, and adjust
focus to get crisp thermal image.
4.
Long press OK button to rectify thermal image.

4.2 Measure Target Temperature

1. Point device to measurement target, and adjust to correct
focus. On the upper-right LCD corner,
spot measurement result. For better accuracy, long press OK
button to perform manual rectify.
2. Select Area (Rect) Measurement to measure max, min, and
average temperature within a rectangle box.
3. It is recommended to press
first, and then apply different and detailed analysis. Press
button one more time to unfreeze.
4. Press
button or
zoom. Upper-left LCD corner displays ×2 when in 2X zoom.
5. When measure result is outside temperature range, screen
display changes to indicate either below or above
temperature range.
8
button to freeze thermal image
button to switch between normal and 2X
*=×× displays the