Voltage Select Switch - Yamaha EF6300iSDE Owner's Manual

Hide thumbs Also See for EF6300iSDE:
Table of Contents

Advertisement

1
2
NO SWITCHING
DURING OPERATION.
120/240V
120V
WHEN SWITCHING TO 120V.
THE 120/240V OUTLET
CANNOT BE USED.
1
2

Voltage select switch

NOTICE
Do not operate the voltage select switch while the
engine is running.
1 120/240V
When the voltage select switch is turned to
"120/240V", the generator supplies both 120V and
240V.
2 120V
When the voltage select switch is turned to "120V", the
generator supplies 120V only.
799-7CK
TIP
If you operate the generator with the voltage select
switch in the 120/240V-position, the electric current
will be limited for the 120V-receptacles.
When you use either receptacle 1 or 2 and recepta-
cle 3 at the same time, the total electric current pro-
3
793-7CKf
vided will be equal to or even less than 22.9A.
For example:
If the 240V-receptacle provides 10A, the 120V-recep-
tacles 1 and 2 can be used up to 12.9A each.
In case the load exceeds 22.9A, the overload indicator
light will turn on and the generator will stop. (At this
moment the segments of the power meter may not
reach 10)
If you operate the generator with the voltage select
switch in the 120V-position, the receptacles 1 and 2
can supply rated current (45.8A).
1 G.F.C.I. receptacle (120V)
2 AC receptacle (120V)
3 AC receptacle (120V/240V)