Application Range - Yamaha EF6300iSDE Owner's Manual

Hide thumbs Also See for EF6300iSDE:
Table of Contents

Advertisement

Application range

When using the generator, make sure the total load is within rated output of a generator.
Otherwise, generator damage may occur.
AC
Power factor
EF6300iSDE
NOTICE
9 Do not overload. The total load of all electrical appliances must not exceed
the supply range of the generator. Overloading will damage the generator.
9 When supplying precision equipment, electronic controllers, PCs, electronic
computers, microcomputer-based equipment or battery chargers, keep the
generator a sufficient distance away to prevent electrical interference from
the engine. Also ensure that electrical noise from the engine does not inter-
fere with any other electrical devices located near the generator.
9 If the generator is to supply medical equipment, advice should first be
obtained from the manufacturer, a medical professional or hospital.
9 Some electrical appliances or general-purpose electric motors have high
starting currents, and cannot therefore be used, even if they lie within the
supply ranges given in the above table. Consult the equipment manufacturer
for further advice.
1
– 5,500W
TIP
1
9 "–" means below.
9 Application wattage indicates when each device is
used by itself.
9 The overload indicator light comes on when total
wattage exceeds the application range. (See page
763-7CKd
13 for more details.)
1 Overload indicator light
0.8 – 0.95
– 4,400W
– 25 –
0.4 – 0.75
(Efficiency 0.85)
– 1,870W

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents