Rated Power Consumption .................................... 1,500W maximum (Microwave oven+Cook top lamp+Ventilation fan)
Microwave Output .................................................. 1,000W (IEC 60705)
Frequency .............................................................. 2,450 MHz ± 50 MHz
Power Supply ......................................................... 120 VAC, 60 Hz
Rated Current ........................................................ 13 Amp. (Microwave oven+Cook top lamps+Ventilation fan)
Magnetron Cooling................................................. Forced Air Cooling
Rectification ........................................................... Rectification Voltage Double Half-Wave
Door Sealing ......................................................... Choke System
Safety Devices ...................................................... Oven Cavity Thermostat:
Magnetron ............................................................. 2M214-39F
High Voltage Capacitor ......................................... Capacitor: 1.0µF, 2.1 KV AC
High Voltage ......................................................... Diode Diode; 350mA, 9.0 KV
Cook top Lamp ...................................................... 125 V, 30 W
Cavity Lamp .......................................................... 125 V, 30 W
Timer ..................................................................... Digital, up to 99 mim. 99 sec. (in each cooking stage)
Tray ....................................................................... Tempered Safety Glass
Overall Dimensions ............................................... 29 15 /16" (W)x16 7 /16" (D)x15 3 /8" (H)
Oven Cavity Size .................................................. 19 7 /8"(W)x14 3 /16"(D)x8 15 /16"(H)
Effective Capacity of Oven Cavity ......................... 1.6 Cu.ft.
Accessories ........................................................... Owner's Manual & Cooking Guide, Installation Manual,

SPECIFICATIONS

Adjustable 100W through 1000W, 10 steps
Fuse(20A)
Primary Interlock Switch
Secondary Interlock Switch
Interlock Monitor
Exhaust Adapter, Exhaust Damper, Mounting Kit and Two
Filters, Rotating Ring Assembly
1-1
Open at 90°C±5°C