Download Print this page

Bryant T1--NAC Installation Instructions Manual

Legacy line-rnc non-programmable thermostat

Advertisement

T1- - NAC
T1- - NHP
LEGACY LINE- - RNC
NON- -PROGRAMMABLE THERMOSTAT
Legacy Line ---RNC Non ---Programmable Thermostat
NOTE: Read the entire instruction manual before starting the

installation.

TABLE OF CONTENTS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Read and follow manufacturer instructions carefully. Follow all
local electrical codes during installation. All wiring must conform
to local and national electrical codes. Improper wiring or
installation may damage thermostat.
Recognize safety information. This is the safety- -alert symbol
When you see this symbol on the equipment and in the instruction
manual, be alert to the potential for personal injury. Understand the
signal words DANGER, WARNING, and CAUTION.
These words are used with the safety- -alert symbol. DANGER
identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which
could result in personal injury or death. CAUTION is used to
identify unsafe practices which may result in minor personal injury
Installation Instructions
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
The Legacy Line- -RNC Series thermostat is an electronic 24VAC,
non- -programmable, manual changeover wall mount thermostat.
This thermostat uses a single setpoint to maintain and control room
temperature in both the heating and air conditioning modes. The
thermostat is designed to maintain +/- - 2_F accuracy. No batteries
are required; temperature, fan, mode, and installer configuration
settings are preserved with power off.

INSTALLATION CONSIDERATIONS

Air Conditioner Model
T1- -NAC, Legacy Line- -RNC Series Model air conditioner
thermostat, may be wired with or without connecting a common
wire between the indoor equipment and the thermostat. However, it
A07110
is recommended to use a common wire whenever possible.
Without a common wire this thermostat becomes "power stealing."
This means it will need to steal a small amount of power from the
equipment to which it is connected.
NOTE:
Not all HVAC equipment is compatible with power
stealing type thermostats. All Bryant equipment is directly
compatible with this thermostat except the Thermostat Conversion
PAGE
Kit, Part #TSTATXXCNV10. For all non- -Bryant equipment,
1
consult the system equipment Installation Instructions before
1
applying this thermostat in a power stealing manner.
Heat Pump Model
1
T1- -NHP, Legacy Line- -RNC Series Model heat pump thermostat,
1
is compatible with all Bryant heat pump systems. It is NOT power
1
stealing and MUST have both the R and C terminals connected to
2
operate properly. This thermostat uses a green LED to indicate
auxiliary heat and emergency heat operation.
2
3

Step 1 - Thermostat Location

3
Thermostat should be mounted:
4
Approximately 5 ft (1.5m) from floor.
S
Close to or in a frequently used room, preferably on an
S
inside partitioning wall.
On a section of wall without pipes or duct work.
S
Thermostat should NOT be mounted:
Close to a window, on an outside wall, or next to a door
S
.
leading to the outside.
Exposed to direct light and heat from the sun, a lamp,
S
fireplace, or other heat- -radiating object which may cause
a false reading.
Close to or in direct airflow from supply registers and
S
return- -air grilles.
In areas with poor air circulation, such as behind a door
S
or in an alcove.

INTRODUCTION

INSTALLATION

Advertisement

loading

Summary of Contents for Bryant T1--NAC

  • Page 1: Table Of Contents

    Heat Pump Model T1- -NHP, Legacy Line- -RNC Series Model heat pump thermostat, is compatible with all Bryant heat pump systems. It is NOT power stealing and MUST have both the R and C terminals connected to operate properly. This thermostat uses a green LED to indicate auxiliary heat and emergency heat operation.
  • Page 2: Step 2- Install Thermostat

    HP or PH controls 1 speed heat pump with 1 stage of aux heat. AC or PC controls 1 speed air conditioner with one stage of heat. Note that this option allows a HP thermostat to be converted to control an AC system.
  • Page 3: Step 4 - Thermostat Operation

    RVS = H Staging Timer If the thermostat is a heat pump model, it has 2- -stage heat capability. With HP operation, there is a 15- -minute delay between the first and second stages of heat. The Y output will energize first, then 15 minutes later, W is allowed to come on if the thermostat determines it is not satisfying the demand.
  • Page 4: Wiring Diagrams

    Fig. 1 - - A/C Thermostat Typical Installation Fig. 2 - - HP Thermostat Typical Installation Catalog No. IIT1---NAC ---02 E2007 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 09/07 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
  • Page 5: Troubleshooting

    What if there is a green light on in the upper corner of the display area? This thermostat uses a green LED to indicate auxiliary heat and emergency heat operation on the Heat Pump model. This green light means one of two things.
  • Page 6 THERMOSTAT LIMITED WARRANTY FIVE- -YEAR LIMITED WARRANTY - - Bryant Heating and Cooling Systems (hereinafter referred to as “Company”) warrants this product to be free from defects in material and workmanship. If a defect is found within five years from date of original installation of product (whether or not actual use begins on that date) Company will provide a new or remanufactured part, at Company’s sole option, to replace any...

This manual is also suitable for:

T1-nhpTb-nacTb-nhp