9-USB
UPDATE(option)
10—Deviceld test
5. Debugging
5.1. General Steps of debugging
According to the requirement of the order, below steps are needed for
appropriate setting.
1) Enter the Factory Menu, enable FAC HOTKEY.
2) Check Project ID and the version of software, release date displayed
at the bottom of Factory Menu.
3) Enter Design Menu, choose SERVICE MENU->Project ID, choose
corresponding Project ID number of the product (Refer to the
"V6-PROJECT -ID0**"in the BOM list).
4) Return to Factory Menu, check the Product model.
5) Choose Factory Menu->NVM RESET and press the right button of the
remote and wait until prompt OK appears.
6) Restart the set
7) According to the requirement of the order, Set the items of SHOP
INIT and Hotel Menu etc.
8) After aging under normal temperature, calibrate ADC and adjust
white balance.
9) Choose Factory Menu ->SHOP and press the button of remote to
initialize the set.
Note: After step 9, Hotel Menu will be disabled by default. Therefore,
USB update, (refer as follow)
Sub-item
Main Upgrade
MEMC Upgrade
HDCP Uprade
Mboot upgrade
CI KEY Upgrate
NVM Upgrade
NVM backup
CH list Upgrade
CH list backup
NetflixESN Upgrade
MAC Upgrade
This item only factory used,
第 9 页共 11 页
Value
Note
Upgrade software
Upgrade MEMC
Upgrade HDCP
Upgrade Mboot
Upgrade CI KEY
Upgrade NVM
Backup NVM
Upgrade CH list
Backup CH list
Upgrade ESN
Upgrade MAC Addre
ok