(*1) See
Handset Reference Drawing
( ).---Should return to OPEN after entering the Test mode.
8.4. X101 Check
The confirmation is made under the Continuous Send mode of TEST MODE.
Equipment: Frequency counter
TP for adjustment: TP_ANT
Measure range: 902.713 MHz ± 5 kHz (1ch) at Test Standby mode in
TEST MODE
().
8.5. Base Unit Reference Drawing
8.6. Handset Reference Drawing